Page 38 - Typical Engineered Industrial Temperature Sensors
P. 38

















Lagging Length ' L1'
Immersion Lenght below Flange ' L3'




Thermocouple Type R, S or B
Platinum / Rhodium
Holding Tube Lenght ' L2 '
Single or Duplex Precious Metal Wire
Flange Size & Mat'l 
Aluminium Connection Head with
TC Wire diameters : 0.25 or 0.5 mm dia
Screwed Gasketed Cover and Captive Chain
as required
Insulated with a 4 mm dia Twin or Four Bore Ceramic 

Insulator ( ALSINT 99.8% Pure Alumina )


1
" NPT St Steel 2
All annular space will be filled with 
Welded Fitting
High Purity Alumina Powder

















High Temperature Fiber
Inner Protection Tube
High Temperature Cement
1/2" od x 3/8" id
High Temperature Cement
High Purity Non Porous Ceramic
( ALSINT 99.8% Pure Alumina with 11/2" NB Sch 40 Holding Tube
Ceramic Terminal Block with 304 St Steel, Inconel 600, Carbon Steel 
one end closed )
Brass Nickel Chromed / or as Specified
Outer Protection Tube
Plated PolarityMarkings
3/4" od x 9/16" id
1/2" NPT Cable Entry
High Purity Non Porous Ceramic
( ALSINT 99.8% Pure Alumina with 

one end closed )




















High Temperature T/C Assembly 
Lynn Blount 3.15.16 
Ceramic Double Thermowell
MJB 3.15.16
PW-1009







   36   37   38   39   40