Page 24 - WHITE BOOK
P. 24

     L ab #
  Chromatography Discussion
(Lab Test Results can be seen on Page 11)
  724681A
A l though sl i ghtl y darker than the new brake f l ui d ref erence thi s spot i s acceptable (PASS). Note there is uniform separation with no phase that is either discolored and no debris field (ring)
   724682A
 PA SS same as 724681A
  724683A
PA SS same as 724681A
   724684A
PA SS same as 724681A
   724685A
PA SS same as 724681A
   724686A
Thissamplehasafaintringdeveloping. Thissampleisconsidereda FAIL. Thelightbrowncoloroftheringsuggestsitisformedby copper,oilordegradedbrakefluid. Thebrakesystemhasnomethod forfilteringorrejuvenatingthefluidandthissystemwill not“get better” with time.
   724687A
 PA SS same as 724681A
  724688A
 FAIL sameas724686A
  724689A
FAIL sameas724686A
   724690A
Although themuch darker than expected thereisuniform separation and no phase changes
Based on the current state-of-the-art this sample is considered PASS
   724691A
 PA SS same as 724681A
  724692A
ThissampleisaFAIL. Thecontaminationringisdarkandhastwo distinct characteristics. A rather narrow but sharp (well define) ring indicating a uniform contaminant and debris dropping out inside of the ring. Thissuggestsparticleofvarioussizesandmorphologies. The color of the ring suggests inorganic contamination
   724693A
 FAIL SAMEAS724686A
  724694A
 FAIL sameas724692A but morecontamination
  724695A
 FAIL sameas724692A but morecontamination
  724696A
 PA SS same as 724690A
  724697A
Thissampleisatoughcall.Thereisaringbuteversofaint. Judgment call ... If sampled regularly PASS until ring further develops.
   724698A
 FAIL about thesameas724692A
  724699A
 FAIL sameas724686A
  724700A
 PA SS same as 724690A
  724701A
 Fail same as 724686A
  724702A
 PASSsameas 724690A
 724703A
 PA SS same as 724690A