Page 209 - Performance-Health-eCatalog-2018-2020
P. 209
Iontophoresis Modalities
Iontophoresis Comparison
Performance Health
Performa Ve
Small
Medium
Large
N
8.8 cm
11.1 cm
18 cm
1.5 cc
2 cc
3 cc
4.0 ma (max)
4.0 mA (max)
4.0 mA (max)
80 mA-min
80 mA-min
80 mA-min
–
Fiber Matrix
Carbon
Smaller areas including fingers and Achilles tendon
Most areas including elbows, knees, wrists, feet and shoulders
Buffered Iontophoresis system. Viscosity-enhancing agent to distribute current evenly. pH-defining agent to optimize drug delivery. Comes in 3 sizes.
12
Travanti MedicalTM
IontoPatch®
80
STAT®
Extra Strength®
SP
Wireless
Y
Active Area
15.5 cm
12 cm
12 cm
8.1 cm
Approximate Fill Volume
1.3 ml
1.0 ml
1.0 ml
1.3 ml
Approximate Operating Current
0.1 mA
0.36 mA
0.25 mA
0.06 mA
Dosage
80 mA-min.
80 mA-min.
120 mA-min.
40 mA-min.
Wear Time
14 hrs. avg
4 hrs. avg
8 hrs. avg
14 hrs. avg
Skin Interface
Hypoallergenic, latex-free
Conductive Element
Screen-printed electrode
Screen-printed electrode with lithium battery
Screen-printed electrode with lithium battery
Screen-printed electrode
Treatment Area
Treats most areas including elbows, knees, wrists, feet and shoulders
Treats smaller areas including fingers and Achilles tendon
Unique Feature
Published outcome study. 6 million clinical applications. No charging station or controller. Wrappable, compressible, weight bearing.
Qty. per Box
6
Chattanooga
TransQFlex
TransQE Small
TransQE Medium
Companion 80
N
N
Y
11.2 cm
10.1 cm
13.4 cm
6.45 cm
2.5cc
1.5-2.0cc
2.5-3.0cc
1.1 cc
4.0 mA (max)
4.0 mA (max.)
1.5v
80 mA-min. (max)
40 mA-min. recommended
80 mA-min. (max.)
40 mA-min. recommended
80 mA-min.
–
–
24 hours
Gel Sponge
Gel Sponge
Hypoallergenic adhesive
SSC
SSC
SSC
Most areas including elbows, knees, wrists, feet and shoulders
Most areas including elbows, knees, wrists, feet and shoulders
Most areas including elbows, knees, wrists, feet and shoulders
Clover shape surrounds treatment area in two directions
Adhesive foam stretches and adheres well under stress. Circle shape.
Battery on board, 24-hr. short circuit protection ensures drug delivery
12
12
6
Chattanooga
Small
Medium
Large
N
N
N
7.2 cm
11.1 cm
16.3 cm
1.5 cc
2.5 cc
3.5 cc
4.0 mA (max)
4.0 mA (max)
4.0 mA (max)
80 mA-min. (max.)
40 mA-min. recommended
–
Gel Sponge
SSC
Smaller areas including fingers and Achilles tendon
Most areas including elbows, knees, wrists, feet and shoulders
SSC electrodes optimize the delivery
of a broad range of drugs. EZ-Fill Window –
peel away window provides easy filling and handling
12
ActivaTek
ActivaPatch
Trivarion
Small
Medium
Large
Butterfly
Wireless
Y
N
Active Area
11.4 cm
7.9 cm
11.4 cm
20.2 cm
11.4 cm
Approximate Fill Volume
2.0 cc
1.5cc
2.0 cc
3.5 cc
2.0 cc
Approximate Operating Current
6v
4 mA
4 mA
4 mA
4 mA
Dosage
40 mA-min. or 80 mA-min.
Up to 80 mA - min.
Wear Time
1.15 hrs for 40 mA or 2.5 hrs for 80mA
–
Skin Interface
Hypoallergenic
Fiber Matrix
Conductive Element
Ag/AgCl-Neg Carbon-Positive
Silver-Silver Chloride
Treatment Area
Most areas including elbows, knees, wrists, feet and shoulders
Smaller areas including fingers and Achilles tendon (small size only)
Most areas including elbows, knees, wrists, feet and shoulders (all other sizes)
Unique Feature
Fully integrated SMART POWER system, no dose controller needed, no saline needed, interactive LED
Unique design conforms well to uneven treatment sites. Large ground electrode surface area lowers sensation and increases comfort.
Qty. per Box
6
12
Illustration A
Matrix is uniformly impregnated with a viscosity-enhancing agent, pH-defining agent and buffering agent.
A Illustration B
Buffered Iontophoresis Electrodes Only from Performance Health
PerformaVe Buffered Iontophoresis Electrodes.
Revolutionary Design. The PerformaVe is a low-profile, buffered iontophoresis electrode designed to maximize drug delivery and speed patient recovery. It uses state-of-the-art technology to optimize the capabilities of a buffered ionto- phoresis system (Illustration A).
Uniform Distribution. A viscosity-enhancing agent distributes current more uniformly and delivers drug evenly (see Illustration B).
33% Higher Drug Delivery. Uses a pH-defining agent to adjust the drug pH to its ideal target.
Some buffered electrodes use granular buffers, leaving non- conducting air pockets that result in uneven distribution.
PerformaVe has a viscosity- enhancing agent that provides uniform current distribution and drug delivery.
554310 Small
554311 Medium $88.41 554312 Large $91.30
B
$86.44
Order online. It’s click & easy: www.performancehealth.com
209