Page 222 - ToroProductCatalogue2016
P. 222
R
25, 40, 50 and 80 mm Century Plus Scrubber Valves
Century Plus Scrubber Valve Series Friction Loss (kPa) vs Flow (Lpm)
Size (mm)
Config.
Flow – LPM
25
20
30
80
100
140
180
Globe
30
35
17
27
53
87
Angle
30
35
17
27
53
87
Size (mm)
Config.
Flow – LPM
40
80
100
125
150
200
250
300
350
400
Globe
7
8
12
18
31
48
72
96
126
Angle
7
8
12
16
26
40
60
81
106
Size (mm)
Config.
Flow – LPM
50
300
350
400
450
500
550
600
Globe
25
32
42
55
65
80
92
Angle
20
28
35
43
54
67
77
Size (mm)
Config.
Flow – LPM
80
550
600
700
800
900
1000
1100
Globe
20
25
32
40
49
60
73
Angle
17
19
25
34
43
54
65
Specifying Information
XX-S
100P
Model
Size
100P - 100 internal bleed and flow control valve
1-25mm 1.5 - 40mm 2-50mm 3- 80mm
Example: A 100P 25mm scrubber valve with internal bleed and flow control = 100P1-S
policy is one of constant improvement and therefore changes in specifications may be made without notice and without incurring liability. Please refer to www.toro.com.au Toro Australia Pty Ltd, 53 Howards Road, Beverley, South Australia, 5009. Phone 1300 130 898, fax (08) 8243 2488. A.B.N. 47 001 310 443
Added Features
• Flow control allows flow adjustment and manual shutoff
• Buna-N valve seat seal
• Encapsulated injection-moulded solenoid with a captive hex plunger
• Positive O-ring seal on inlet plug prevents leaks without damaging seal threads
• Moulded-in and anchored studs allow positive bonnet attachment and removal
• Brass flow control stem on 50 and 80mm models
• Easily serviced without removal from the system
• Five-year warranty
Operating Specifications
• Flow range: 20-1100 Lpm
• Pressure range: 70-1379 kPa
Electrical Specifications
• Solenoid: 24 VAC
• Inrush volt-amp: 24 VAC, 9.6 VA • Inrush current: .4 amp
• Holding volt-amp: 24 VAC, 4.8 VA • Holding current: .2 amp
Dimensions (D × W × H)
D (mm)
W (mm)
H (mm)
100P1-S
121
93
172
100P1.5-S
121
93
185
100P2-S
197
156
242
100P3-S
210
156
274
Optional Accessories*
• OmniReg® 35-210 kPa regulator (OMR- 30)
• OmniReg 35-700 kPa regulator (OMR- 100)
• DC latching solenoid (DCL)
Note: Maximum pressure for a valve that utilizes latching solenoid is 820 kPa.
• Weatherproof gauge (SPK-100)
* Optionalaccessoriesarefield-installable. Must specify separately if required.