TORO Commercial Controller Features ‘At a Glance’
Number of Stations Number of Programs Minimum Run Time Max Run Time
Run Time Units Starts Per Program Schedule
-Interval
-Interval Day exclusion -Odd/Even -Odd/EvenDay exclusion
Time keeping Back up Program Memory Armchair Programming Water Budget %
TMC 424E
4,8,12,16,20,24
4
1 second
8 Hours
seconds or minutes 1 to 16
7 Day
1 to 31 Days Yes
Yes
Yes
9V Battery Non-Volatile Yes
0 to 200% Program Yes
Yes
Yes
Custom Command
12,15,18,24,36,48 4
1 minute
10 Hours
minutes
1 to 16
7 Day
1 to 30 Days
-
Yes
Yes
9V Battery
Non-Volatile
Yes
10 to 200%
Program
Yes
Yes
Yes
-
-
-
240V AC
1to7Days
Yes
Yes
-
Yes
Program
-
-
Outdoor Plastic & Metal Yes
TMR-1
up to 16KV
up to 16KV
-
24VAC
2
5
5 Years
Yes
Yes
- Yes -
- - - - - -
Yes -
-
TDC Standalone
100,200 10
1 minute 99 minute minutes
6
14 Day
1 to 30 Days
- Yes -
-
Non-Volatile
No
0-200%
Global, Prog, Station
-
Yes
Yes
5
Yes
-
240V AC upto31Days
Yes
-
-
6
Station
-
-
Metal Outdoor
Yes
TMR-1
-
Yes + External
Yes
15,20 VDC Latching 2
20
1 Year
Yes
Yes
2
Yes R/S & P/S
- - - -
stat/prog various options -
4500m 2.5mm2 -
Yes Yes
-Water Budget Adjust Per
Program\Start Time Stacking
Simultaneous Watering
Individual Program Erase
CycleRepeat -
Delay Between Stations -MV/ PS On/Off in Delay
Power Supply ManualRainDelay Rain Switch
-Rain Switch Byass -Programable Rain Switch
Master Valve/ Pump Start -MV/PS Programable Per -MV/PS delay
-N/O M/V for line protection
Cabinet / Housing Type Lockable Cabinet
Remote Option
Input Surge Protection
Output Surge Protection
Valve Test Program
Station Output Voltage
Max Valves per Station @.25A Max Valves Operating @.25A Warranty
Electrical Over Current -Station Fault Skip
Sensor Inputs
-Sensor Stop
-Flow Rate Sensor
-Flow Over/Under Monitoring -Over Flow Shut Off
-Under Flow Shut Off Pause
Event Day Skip
Max Cable Run Pedestal Option
PC Central Compatible DayChange
250
5secto30min Yes
240V AC 1to14Days Yes
Yes & Bypass till midnight by program
Up to 4
Stat/Prog to any MV/PS
1 to 60 seconds
yes
Indoor/ Outdoor
Yes on OD
TMR-1 & EZ-Remote
Standard & High 6KV Yes
24VAC
2
4
5 Years
-
Short Detection 3 (optional)
Yes
Yes
Yes
Yes
Yes
- - - - - -
Company policy is one of constant improvement and therefore changes in specifications may be made without notice and without incurring liability. Please refer to www.toro.com.au Toro Australia Pty Ltd, 53 Howards Road, Beverley, South Australia, 5009. Phone 1300 130 898, fax (08) 8243 2488. A.B.N. 47 001 310 443