Application
For use in viticultural, horticultural, greenhouse and landscape irrigation applications. Its pressure compensating ability makes it suitable for use in steep or undulating situations or where longer run lengths need to be achieved.
Features
DRIPMAXX® PC (with Maxxi dripper) In-line pressure compensating drip tube
• Four flow rates available:- 0.85, 1.2, 1.6 and 2.1 Lph.
• Large pre-entry filter area helps to screen water-borne particles.
• Proven pressure compensating mechanism for long runs, steep and undulating terrain.
• Large pipe diameters create the ability to run the drip tube further.
• Diameters made to suit Australian standard and other fittings.
• Emitter has “self-flushing” action at the beginning and end of each irrigation cycle helping to reduce the risk of blockages.
Design Information
Nominal Diam/Flow
15/0.85
15/1.2
15/1.6
15/2.1
19/0.85
19/1.2
19/1.6
19/2.1
21/0.85
21/1.2
21/1.6
21/2.1
ID (mm)
15.4
15.4
15.4
15.4
19
19
19
19
20.8
20.8
20.8
20.8
Emitter Index (in compensating range)
0
0
0
0
0
0
0
0
0
0
0
0
Emitter Constant
0.85
1.2
1.6
2.1
0.85
1.2
1.6
2.1
0.85
1.2
1.6
2.1
Emitter kd barb factor
0.2
0.2
0.2
0.2
0.09
0.09
0.09
0.09
0.08
0.08
0.08
0.08
Roughness Factor, C
140
140
140
140
140
140
140
140
140
140
140
140
Minm Compensating Pressure (kPa)
100
100
100
100
100
100
100
100
100
100
100
100
Minimum Recommended Pressure (kPa)
100
100
100
100
100
100
100
100
100
100
100
100
Maximum Pressure (WT = 0.9mm)
350
350
350
350
350
350
350
350
350
350
350
350
Filtration (micron) - sand
125
125
125
125
125
125
125
125
125
125
125
125
Speci cations
Nominal Diameter
15mm
19mm
21mm
Diameters ID
15.4
19mm
20.8
Flow Rates
0.85, 1.2, 1.6, 2.1
Lph
0.85, 1.2, 1.6, 2.1 Lph
0.85, 1.2, 1.6, 2.1 Lph
Std. Wall Thickness
0.9mm
0.9mm
0.9mm
Compensating Range
100-350 kPa
100-350 kPa
100-350 kPa
Minimum Recommended Pressure
100 kPa
100 kPa
100 kPa
Maximum Pressure
350 kPa (0.9mm wall)
350 kPa (0.9mm wall)
350 kPa (0.9mm wall)
Standard Coil Length
15mm – 350m Non-standard leng
ths for qualifying order
19mm – 350m
Non-standard lengths for qualifying order
21mm – 350m
Non-standard lengths for qualifying order
Standard emitter spacings
0.3, 0.4, 0.5, 0.6,
0.75, 0.9, 1.0, 1.5m
0.3, 0.4, 0.5, 0.6, 0.75, 0.9, 1.0, 1.5m
0.3, 0.4, 0.5, 0.6, 0.75, 0.9, 1.0, 1.5m
Ordering Information
X
M
Maxxi pressure compensating
aa
bb
cc
dd
eee
ID
Wall thickness
Emitter flow
Spacing
Special coil length (m)
15 – 15.4mm 19 – 19mm 21 – 20.8mm
09 – 0.9mm 10–1mm
08 – 0.85 Lph 12–1.2Lph 16–1.6Lph 21–2.1Lph
030 – 30cm 040 – 40cm 050 – 50cm 060 – 60cm
075 – 75cm 090 – 90cm 100 – 100cm 150 – 150cm
Example: XM190916100 – DripMaxx PC with Maxxi dripper, 19mm, 1.6 Lph emitter, 0.9mm wall thickness, emitter every 1.0 metre, standard coil length. Example : XM21091630-220 – DripMaxx PC with Maxxi dripper, 21mm, 1.6 Lph emitter 0.9 mm wall thickness, emitter every 30cm, 220 metre coil length. Minimum order quantity: 5000 metres.
Company policy is one of constant improvement and therefore changes in specifications may be made without notice and without incurring liability. Please refer to www.toro.com.au Toro Australia Pty Ltd, 53 Howards Road, Beverley, South Australia, 5009. Phone 1300 130 898, fax (08) 8243 2488. A.B.N. 47 001 310 443