*INSTALLATION*
Electrical connection
Total power rating
See data plate
Connection data
Residual current device
Installation
We recommend that you connect the steam oven to the power supply using a suitable switched electrical socket. This makes it easier to perform servicing work. The socket must be easily ac- cessible after the steam oven has been installed.
The connection data is quoted on the data plate. Please ensure these match the household mains supply.
Risk of damage from incorrect connection.
Installation, repairs and other main- tenance work by unqualified persons could be dangerous. Miele cannot be held liable for unauthorised work. Miele cannot be held liable for dam- age or injury caused by the lack of or inadequacy of an on-site earthing system (e.g. electric shock).
If the plug is removed from the con- nection cable or if the cable is sup- plied without a plug, the steam oven must be connected to the electrical supply by a suitably qualified electri- cian.
If the socket is no longer accessible, or if a hard-wired connection is in- stalled, an additional means of dis- connection must be provided for all poles. A suitable means of discon- nection would include switches with an all-pole contact gap of at least
3 mm. These include circuit break- ers, fuses and contactors. The re- quired connection data is provided on the data plate. Please ensure that these details match the electrical supply.
After installation, ensure that all elec- trical components are shielded and cannot be accessed by users.
For extra safety, it is advisable to pro- tect the steam oven with a suitable re- sidual current device (RCD) with a trip range of 30 mA.
Replacing the mains connection cable
When replacing the mains connection cable, please use cable type H 05 VV-F with a suitable cross-section. These cables are available from the manufac- turer or from Miele Service.