Page 27 - MATRIX MANUAL HTML
P. 27
x
QRH 2-17
NON-QRH
ETOPS Significant System
An equipment cooling valve is not in the commanded position.
VALVE light stays illuminated:
After QRH procedures complete..Contact SOC to update condition. Result of procedure leaves the Pressurization normal . Non-normal pressurization could result (Pressurization- ETOPS significant GROUP ). Pilot can expect to Divert or Return to Field. Consider over weight landing possibility. If prior to EET do not enter ETOPS. If past EEP may continue with concurrence.
VALVE light stays illuminated:
Result of procedure leaves the Pressurization normal . Non-normal pressurization could result (Pressurization-ETOPS significant GROUP ). Pilot can expect to Divert or Return to Field. Consider over weight landing possibility. If prior to EET do not enter ETOPS. If past EEP may continue with concurrence.
MX procedures that could follow.