Page 37 - MATRIX MANUAL HTML
P. 37

  x
QRH
3-2
NON-QRH
ETOPS Significant System
 Messages: CAPT PITOT
Condition: The captain’s pitot probe heat is failed.
 After QRH procedures complete..Contact SOC to update condition. Result of procedure leaves the Pressurization normal but with a single source available. Non-normal pressuriation results in a Significant System compromised
(Pressuriation-ETOPS significant GROUP ). Pilot can expect to Divert or Return to Field. Consider over weight landing possibility. If prior to EET do not enter ETOPS. If past EEP may continue with concurrence taking into account remaining time to destination.
 Pressurization normal but with a single source available. Non-normal pressurization results in a Significant System compromised (Pressuriation-ETOPS significant GROUP ). Pilot can expect to Divert or Return to Field. Consider over weight landing possibility. If prior to EET do not enter ETOPS. If past EEP may continue with concurrence taking into account remaining time to destination.
 MX procedures that could follow.