Page 31 - Great Northern Conference 2020: GAUA
P. 31
CTA10
CTA9
CTA8
WC
CTA7
0x250
200Ø
500x250
52050x
550x250
200Ø
200Ø
CONDENSATE DRAIN CONNEWCITHSIINTWO.CSTACK
SEE DWFOGR7V11A0L-VKER-M700 ARRANGEMENTS
FD
250Ø FD
G FCU 7/2 (SIZE 20) LLED TO 8/2
NEW FCU 12/2 (SIZE 63)
EXISTING FCU 11/2 (SIZE 32) RE-LABELLED TO 13/2
APPROXIMATE LOCATION OF EXISTING PIPE TRAY ROUTE
EXISTING FCU 8/2 (SIZE 20) RE-LABELLED TO 9/2
EXISTING FCU 13/2 (SIZE 32) RE-LABELLED TO 16/2
EXISTING FCU 14/2 (SIZE 20) RE-LABELLED TO 17/2
EXISTING FCU 12/2 (SIZE 32) RE-LABELLED TO 15/2
NEW CIRCULAR SUPPLY DIFFUSERS EXTEND EXISTING DUCT FOR
CONNECTION TO EXTRACT VALVE & INTO MAIN EXTRACT DUCT
Your experts in heating, cooling, ventilation & plumbing
3456789
EXISTING FCU 3/2 (SIZE 20) RELOCATED LOCALLY TO THIS POSITION
EXISTING FCU 5/2 (SIZE 20) RELOCATED LOCALLY TO THIS POSITION & RE-LABELLED 4/2
EXISTING FCU 4/2 (SIZE 20) RE-LABELLED TO 5/2
NEW UNIT 6/2 (SIZE 63) TO REPLACE EXISTING UNIT 4/2
EXISTING FCU 6/2 (SIZE 20) RE-LABELLED TO 7/2
EXISTING FCU 1/3 (SIZE 20) RELOCATED LOCALLY TO THIS POSITION
250Ø FD
G21
FD
200Ø
G23
200Ø
200Ø
VCD
200Ø
G26
VCD
200Ø
G27
400x220
FCU 6/1 (SIZE 20) RELOCATED FROM GROUND FLOOR & RE-LABELLED TO 3/3.
250Ø FD
VCD
VCD
VCD
NOTE:-
NEW FCU 14/2 (SIZE 63)
VCD
VCD
VCD FD
250Ø FD
VCD
VCD 200Ø
VCD
200Ø VCD
G28
400x250
G22
VCD
G24
VCD
VCD
VCD
VCD
VCD
900x250
VCD
550x220
UP 40mm
VCD
VCD
VCD
VCD
VCD
200Ø
200Ø
VCD 200Ø
VCD
500x220
200Ø
150Ø
400x VCD 200
VCD
VCD
200Ø
200Ø
200Ø
FGCRUOU7/N1D(SFIZLEOO20R) &RERLEO-LCABTELDLEFDROTMO 4/3.
250Ø FD
FD
VCD VCD
200Ø
FD FD FD
VAV
VCD
VCD
200Ø 200Ø
NEW SECTION OF DUCTWORK/GRILLES SHOWN IN BOLD. ANY FIRE DAMPERS/VCDs TO BE REPLACED TO SUIT NEW SIZE OF DUCTWORK & BE INSTALLED WITH MANUFACTURER'S INSTALLATION FRAME.
125Ø
450x250
VCD
G23A
EXISTING FCU 4/3 (SIZE 32) RELOCATED LOCALLY TO THIS POSITION & RE-LABELLED 6/3
200Ø
VCD
200Ø
200Ø
G24
G25
UP 40mm
FD
750x250
125Ø
200Ø
350x 250
750x250
VCD
CO2
VCD VCD
UP
LEED | SKA | BREEAM | WELL BUILDING
• ISO 14001 Conformance • TM44 Assessment • Free FGAS Registers • Paperless Reporting
Airmaster Air Conditioning Ltd, Wetherby House, Park Hill, Swallownest, Sheffield, S26 4UN
Tel: 0114 288 9911 Web: www.airmaster.uk.com
500x 800 400
550x
VCD
N(SEIZWEF3A2N) COIL UNIT 7/3
450x250
FD
CONVECTOR SIZE 6
VCD
VCD
CTA6
150Ø VCD
FD 250Ø 200Ø
VAV VCD
CONVECTOR SIZE 6
UP
CUT & CAP EXISTING DUCT
EXISTING FCU 9/3 (SIZE 32) RELOCATED LOCALLY TO THIS POSITION & RE-LABELLED 8/3
EXISTING FCU 7/3 (SIZE 20) RE-LABELLED TO 13/3
EXISTING FCU 6/3 (SIZE 40) RE-LABELLED TO 9/3
D
EXISTING FCU 8/3 (SIZE 40) RE-LABELLED TO 12/3
NEW FCU 11/3 (SIZE 32) REPLACES RELOCATED UNIT 8/3 (WAS 9/3)
E
FD
350x250
FD
200Ø
VCD
VCD
VCD
VCD
VCD
150Ø
VCD
400x200
WC CO2
WC
WC WC CO2
150Ø VCD
VCD
VCD
VCD
VCD
G29
G30
VCD
150Ø
200Ø
200Ø
200Ø
200Ø
200Ø
150Ø
200Ø
CTA5
125Ø
200Ø 200Ø
125Ø 200Ø
225Ø
250Ø
350x200
200Ø
150Ø
125Ø
125Ø
125Ø
150Ø
150Ø
200Ø 300x100
250Ø
125Ø
125Ø
900x250
200Ø
200x100
250x100
200Ø
200Ø
CO2
150Ø
150Ø
200Ø
150Ø
CO2
150Ø
200Ø
150Ø
150Ø
WC CO2
200Ø
200Ø