Page 431 - climatizzazione mobile giugno 2018 2
P. 431
58
01
REGOLATORE DOPPIA MEMBRANA
DOUBLE MEMBRANE CLOSING REGULATOR
Code
Model/Ø
conf./pack
euro
40041 B MIN
3/4”FF.
1
220,70
40042 B MIN
1”FF.
1
220,70
40043 B MIN
1 1/4” FF.
1
338,70
40044 B MIN
1 1/2” FF.
1
338,70
40045 B MIN
2”FF.
1
364,60
REGOLATORE DOPPIA MEMBRANA
DOUBLE MEMBRANE CLOSING REGULATOR
Code
Model/Ø
conf./pack
euro
40202
3/4”FF.
1
230,25
40203
1”FF.
1
230,25
40204
1 1/4” FF.
1
302,00
40205
1 1/2” FF.
1
302,00
40206
2”FF.
1
333,95
VERSIONE A MEMBRANA RINFORZATA +20%
REINFORCED MEMBRANE VERSION + 20%
REGOLATORE DOPPIA MEMBRANA
DOUBLE MEMBRANE CLOSING REGULATOR
Code
Model/Ø
conf./pack
euro
40238
DN 32 PN16
1
224,50
40239
DN 40 PN16
1
224,50
40240
DN 50 PN16
1
314,85
40207
DN 65 PN16
1
750,40
40208
DN 80 PN16
1
756,10
40209
DN 100 PN16
1
1.268,80
VERSIONE A MEMBRANA RINFORZATA +20%
REINFORCED MEMBRANE VERSION + 20%
REGOLATORE DOPPIA MEMBRANA
DOUBLE MEMBRANE CLOSING REGULATOR
Code
Model/Ø
conf./pack
euro/pz.
40212
3/4”FF.
5
241,05
40213
1”FF.
5
241,05
40214
1 1/4” FF.
1
332,45
40215
1 1/2” FF.
1
332,45
40216
2”FF.
1
358,80
VERSIONE A MEMBRANA RINFORZATA +20%
REINFORCED MEMBRANE VERSION + 20%
0497
Regolatore doppia membrana a chiusura CON FILTRO e valvola di blocco per minima pressione a valle. Mod. FRG/2MB-MIN
Portata / Capacity
Pressione in entrata / Inlet pressure
P2 standard
Taratura blocco / Shut off setting Entrata-Uscita / Inlet - Outlet
Temperatura di esercizio / Working temperature
Double membrane closing regulator WITH FILTER and minimum pressure shut off valve. FRG/2MB-MIN model
Vedi diagramma / See diagram
1 bar
(3/4” - 1”) 15-30 mbar - (1”1/4 - 1”1/2) 12-35 mbar - (2”) 20-45 mbar 8÷22 mbar
Vedi speci ca / See speci cation
-15°/+60°C
REGOLATORI E STABILIZZATORI PER GAS METANO
REGULATORS AND STABILIZERS FOR METHANE GAS
0497
2 Bar
Regolatore doppia membrana a chiusura SENZA FILTRO Mod. RG/2MB-max
Con blocco di massima pressione a valle
Attacchi lettati - Pressione in entrata max 2 bar
Double membrane closing regulator WITHOUT FILTER RG/2MB-max model With outlet max pressure shut off device
Threaded connections - Maximum inlet pressure 2 bar
0497
2 Bar
Portata / Capacity
Pressione in entrata / Inlet pressure
P2 standard
Taratura blocco / Shut off setting Entrata-Uscita / Inlet - Outlet
Temperatura di esercizio / Working temperature
Regolatore doppia membrana a chiusura SENZA FILTRO Mod. RG/2MC Attacchi angiati - Pressione in entrata max 2 bar
Portata / Capacity
Pressione in entrata / Inlet pressure
P2 standard
Entrata-Uscita / Inlet - Outlet
Temperatura di esercizio / Working temperature
Vedi diagramma / See diagram
2 bar
(3/4” - 1”) 20-40 mbar - (1”1/4 - 2”) 13-23 mbar 30÷450 mbar
Vedi speci ca / See speci cation
-15°/+60°C
Double membrane closing regulator WITHOUT FILTER RG/2MC model Flanged connections - Maximum inlet pressure 2 bar
Vedi diagramma / See diagram 2 bar
(DN 65 - DN 100) 15-27 mbar Vedi speci ca / See speci cation -15°/+60°C
Double membrane closing regulator WITH FILTER FRG/2MB-max model
With outlet max pressure shut off device
Threaded connections - Maximum inlet pressure 2 bar
Vedi diagramma / See diagram
2 bar
(3/4” - 1”) 20-40 mbar - (1”1/4 - 2”) 13-23 mbar 30÷450 mbar
Vedi speci ca / See speci cation
-15°/+60°C
0497
2 Bar
Regolatore doppia membrana a chiusura CON FILTRO Mod. FRG/2MB-max
Con blocco di massima pressione a valle Attacchi lettati - Pressione in entrata max 2 bar
Portata / Capacity
Pressione in entrata / Inlet pressure
P2 standard
Taratura blocco / Shut off setting Entrata-Uscita / Inlet - Outlet
Temperatura di esercizio / Working temperature
Per i prodotti dove non è evidenziato l’uso per Biogas chiedere fattibilità. For products where biogas employ is not clearly stated please ask feasibility. TECNOGAS catalogo/listino prezzi 2016 catalogue/price list