Page 487 - 2020-2021 Catalogue
P. 487

BATTERY CHARGING RELAYS
Specifications: I300	Intermittent Rating: Ic	Continuous Rating: Ioc	(Combine) Amperage
Operating Current Ioc	(Open) Amperage Operating Current
Maximum Cable Size Terminal Stud Size Maximum Torque Relay Contact Position Combine (30 sec.)
(2 min.) Open	(10 sec.) (30 sec.)
Open High Under Voltage Lockout Regulatory
115A 65A 175mA
15mA
1/0 AWG 1/4"-20 75 in-lb (8.5Nm)
13.6V DC 13.0V DC 12.35V DC 12.75V DC 16.0V DC 9.5V DC
marked, ISO 8846 Meets UL 1500 and SAE J1171 external protection requirements IP67 - protected against immersion up to 1 meter for 30 minutes
ignition
DC MINI ACR AUTOMATIC CHARGING RELAY Automatically combines batteries during charging, isolates batteries when discharging or at rest
FEATURES:
• 65 Amp continuous rating manages the charging current from alternators up to 65 Amps found on most outboards and many inboard engines
• Compact case design allows surface and panel mounting • Senses charging on two battery banks • Snap-on cover insulates terminal connections • LED indicates ACR status
• 1/4" x .032" male quick connect terminal for ground • 5/8" (16 mm) stud length to accept multiple cable terminals • 12V DC voltage input
12V DC
210A 120A 175mA
15mA
1/0 AWG 3/8"-16 (M10) 140 in-lbs.
13.6V DC 13.0V DC 12.75V DC 16.0V DC
12.25V DC
marked, ISO 8846 Meets UL 1500 and SAE J1171 external protection requirements IP67 - protected against immersion up to 1 meter for 30 minutes
24V DC
210A 120A 115mA
15mA
1/0 AWG 3/8"-16 (M10) 140 in-lbs.
27.2V DC 26.0V DC 25.5V DC 30.0V DC
24.5V DC
Specifications: I300	Intermittent Rating: 5 min. Ic	Continuous Rating: Ioc	(Combine) Amperage
Operating Current Ioc	(Open) Amperage Operating Current
Maximum Cable Size Terminal Stud Size Maximum Torque Relay Contact Position Combine (30 sec.)
(2 min.) Open Low(30 sec.)
Over Voltage Lockout
Auxiliary Priority – Optional Feature
Open Low(30 sec.)
Regulatory
ignition
DC BATTERYLINKTM ACR AUTOMATIC CHARGING RELAY With Auxiliary Battery Priority
Automatically shares single source of charge with auxiliary battery
FEATURES:
• 120 Amp continuous rating manages the charging current from high output alternators found in many specialty vehicles
• 12/24V DC auto ranging voltage input • Senses charging on two battery banks • Side and bottom knockouts for cable connections • Clip-on cover insulates terminal connections • 7/8" (22 mm) stud length to accept multiple
cable terminals • Integrated LED indicates ACR status • 1/4" x .032" male quick connect terminals for ground
and optional connections
OPTIONAL FEATURES: • Auxiliary Battery Priority shares the alternator charge
with the auxiliary battery longer when engine is running • Remote LED remotely indicates
ACR status – requires optional LED (See Page 346)
With Cover
ORDER NO.
738-76010
ORDER NO.
738-76110
Mfr. No.
7601
Mfr. No.
7611
For more information see: www.bluesea.com
461


































































































   485   486   487   488   489