Page 81 - Demo
P. 81
XR850 SELECTION GUIDE
XR850 MODEL XR850 US
CB - 0 625 CA - 0 0 750 CC - 0 875
CE - 1 000
CF - 1 1 125 CH - 1 375 C8 - 1 500 CJ- 1 625 CK - 1 750 CL - 1 875
CM - 2 000
CN - 2 2 125 CQ - 2 2 250 CP - 2 375 CR - 2 500 CT - 2 2 625 CS - 2 771 C2 - 2 2 875
CU - 3 000
CW - 3 250 CY - 3 3 375 CZ - 3 421 CV - 3 3 438 C3 - 3 3 500 TD - 3 625 TG - 3 750* T4 - 3 875* T1 - 4 000* T7 - 4 250* T6 - 4 500*
ROTOR CODE Metric
DE - 19mm (h7) DF - 30mm
DJ - 42mm
DP - 60mm
DT - 70mm (h7) DS - 70mm (m6) DZ - 80mm (h7) DY - 80mm (f6) D2 - 80mm (g6) D3 - 90mm (m6) MD - 93mm (g6) M4 - 95mm (m6) M8 - 110mm (g6) COVER STYLE
B - Thru Shaft Cover w/ inboard seal plate
D D - - Dome
F F F - - - Flat Flat Cover Cover N - - Flat Flat Cover Cover w/ inboard seal plate
T T - Thru Shaft Cover X - None
LINE DRIVER
See Table Below
LEFT MODULE
PPR F - - 60 C - - - 64
G - - - 100 H - - - 120
A - - - 128
L - - - 240
N - - - 256
P - - - 300
E - - - 360
B - - - 480
Q - - - 500 R - - - 512
S - - - 600 V - - - 900
J - - - 960
Y - - - 1024 Z - - - 1200 6 - - - 1800 3 - - - 2000 4 4 - - - 2048 5 5 - - - 2500 D - - - 4096 8 8 - - - 4800 9 - - - 5000 0 0 0 0 - - - special X - - none
LINE DRIVER
See Table Below
RIGHT MODULE
PPR F - - 60 C - - - 64
G - - - 100 H - - - 120
A - - - 128
L - - - 240
N - - - 256
P - - - 300
E - - - 360
B - - - 480
Q - - - 500 R - - - 512
S - - - 600 V - - - 900
J - - - 960
Y - - - 1024 Z - - - 1200 6 - - - 1800 3 - - - 2000 4 4 - - - 2048 5 5 - - - 2500 D - - - 4096 8 8 - - - 4800 9 - - - 5000 0 0 0 0 - - - special X - - none
CONNECTOR OPTIONS
See Table Below
SPECIAL OPTIONS
000
- - None
003 - - Include analog signal converter (K661) 004 - Super sensor shielding 4XX - Special PPR 700 - Large Motor Stator Adapter
* Set Screw Rotor only
Voltage In / Out Line Driver Code
Description
ATE / IECEx Zone 1 1 & 21 ATEX / IECEx Zone 2 2 2 & 22 Class I I I & II Div 1 & Zone 0 Class I I I & II Div 2 Listed
Class I I I & II Div 2 Recognized
5-7 / 5 5 H ✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
5-24 5-24 / 5-24 5-24 7 ✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
5-7 / 5 5 FG
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
5-24 5-24 / 5-24 5-24 R ✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
5-24 5-24 / 5-24 5-24 Code
Required Isolator XRB3 None
XRB3 None
None
A 10 Pin MS W/O Plug - Std Phasing
B 10 Pin MS W/O Plug - Dynapar Phasing
E 7 Pin MS W/Plug A-quad-B - - - Std Phasing
F 7 Pin MS W/Plug A A A\ - Std Phasing
J 7 Pin MS W/Plug A B Z - Std Phasing
K 7 Pin MS W/Plug A A A\ B B B\ - Std Phasing
S S 7 Pin MS W/Plug A-quad-B - - - Dynapar Phasing
T 7 Pin MS W/Plug A A A\ - Dynapar Phasing
U 7 Pin MS W/Plug A B Z - Dynapar Phasing
V 7 Pin MS W/Plug A A A\ B B B\ - Dynapar Phasing
P P P Large Industrial Style - Std Pinout & Plug G Large Industrial Style - Northstar Pinout & Plug R 10 Pin mini Twist Lock with Plug W Flexible Cable with Sealing Gland
4 Conduit Box Terminal Block & 1/2" NPT
5 Conduit Box Terminal Block 3/4" NPT+Chord
6 Conduit Box Terminal Block & 1" NPT
7 Conduit Box Terminal Block & 25mm
THE THE MOST RELIABLE ENCODERS ENCODERS IN THE THE WORLD
| AVTRON ENCODERS ENCODERS 78