Page 9 - Laqfoil Technical Catalog
P. 9

 Dimensions & Weight:
Technical Specifications
  Finish
  Thickness
   Weight
  PVC
   ≈ 0.18 - 0.20mm
    170 - 180 g/m2
  Descor canvas textured membrane
  0.35mm - 0.44mm
   185 - 245 g/m2
   Hygrometry: Permeability to water vapour
Vapour Tested NF EN 14716 § 4.1.3
In view of the results of these measurements, the membrane may be considered to be a very effective impermeable barrier to water. Stretch ceiling has received awards from the Swimming Pool and Allied Trades Association (SPATA UK) for its vapour barrier properties.
Mechanical Characteristics (PVC):
Our canvas textile’s tensile strength is better than 350N.
Dimensional stability: Dimensionally stable from -35°C to +95°C
Material retention: Shape-retentive molecules - membrane ‘remembers’ its original shape. May require heating for full return to shape if stretched. Once installed, a stretch ceiling assembly can support the weight of one or
two people (as shown), or 100 litres of water on an area of one square metre.
Reflection and light transmission characteristics:
   For hygrometric degree < 65% RH = 0.0030 g/hr m2 mm Hg
   For hygrometric degree > 65% RH = 0.0045 g/hr m2 mm Hg
   Strength
 Longitudinal
   Transversal
 Tear strength
  196.50 kg/cm2 or 2788.34 lb/in2
    220.80 kg/cm2 or 3133.15 lb/in2
   Elongation at rupture
 231%
   309%
   Tensile strength (ISO weight standard)
S = 1.60 dN
  S = 2.00 dN
 Elongation at rupture (ISO weight standard)
 E = 170%
  E = 255%
       Membrane
   % Reflection
  % Transmission
  02011 High Gloss Opaque White
   ≈ 78.8
  ≈ 9.6
 01010 Matte Opaque White
 ≈ 81
 ≈ 9.8
 04013 Matte Translucent White
 ≈ 43.8
 ≈ 72