Page 35 - Ei Electronics Product Selector Guide
P. 35

   Action
   None
 Follow Fire Evacuation Procedure
   Follow CO Evacuation Procedure
 Follow Evacuation Procedure
   Reconnect AC mains power
 Replace the Alarm. Temporarily silence the Chirps by pressing the Test/Hush button. (Chirp silence last for 12 hours)
   Replace the Alarm
  Replace the Alarm. Temporarily silence the Chirps by pressing the Test/Hush button. (Chirp silence lasts for 12 hours)
  Cause
   Standby Condition
 Fire Alarm Condition
   CO Alarm Condition
 Activated by another alarm in the interconnected system. Alarm with the Red LED or icon flashing is the detecting alarm
   AC Mains off
 Low back-up battery
   Sensor Fault
  End of Life
 Observe & Hear
  Sound
    Full Fire alarm tone
   Full CO alarm tone
 Full Fire alarm tone
    1 x short Chirp
   2 x short Chirps
  3 x short Chirps
 Icon Display (Ei3028 Only)
     Flashing
   Flashing
            Red LED
  Flashing rapidly
  Flashing rapidly
       Amber LED
            Flash x1
Every 48 Seconds
   Flash x2
Every 48 Seconds
  Flash x3
Every 48 Seconds
 Green LED
  ON
  ON
  ON
  ON
  Flash x1
Every 48 Seconds
  ON
  ON
   ON
   Alarm Indicator Guides
Ei3000 Series Alarm Indicator Guide
Refer to the Instruction Manual for a complete list of indicators
 35