C SERIES CURTAINWALL WIND LOAD CHART
2"
11'-6" 11'-0" 10'-6" 10'-0"
9'-6"
9'-0"
8'-6"
8'-0" A
C 19
7'-6"
B C D
7'-0" E F
6'-6" 6'-0" 5'-6"
G
I x-x = 2.18 IN^4 S x-x = 0.869 IN^3
3'-0" 3'-6" 4'-0" 4'-6" 5'-0" 5'-6" 6'-0" 6'-6" H. MULLION SPACING ( x )
W/ ALUM BLOCKING COMBINED
C 19
11'-6" 11'-0" 10'-6" 10'-0"
9'-6" 9'-0" 8'-6" 8'-0" 7'-6" 7'-0" 6'-6" 6'-0" 5'-6"
ALUM BLOCKING
A
B
C
D
E
F G
I x-x = 3.147 IN^4 (Comb.) S x-x = 1.42 IN^3 (Comb.)
A = 20.0 PSF B = 22.5 PSF C = 25.0 PSF D = 27.5 PSF E = 30.0 PSF F = 32.5 PSF
DEFLECTION = L / 175
3'-0" 3'-6" 4'-0" 4'-6" 5'-0" 5'-6" 6'-0" 6'-6" H. MULLION SPACING ( x )
50 Years of Manufacturing Innovative Aluminum Doors, Frames, Curtain Walls, Windows and Vents
Bay 108 - 1626 115 Ave. N.E. Calgary, Alberta T3K 2E4 Phone: 403-250-9290 Fax: 403-291-0599 Toll Free: Phone: 1-877-919-0906 Fax: 1-877-919-0905
www.metroglass.ca
1 1/4"
2 3/4'
4 3/4'
V. MULLION SPAN ( L )
V. MULLION SPAN ( L )
3/4"
G = 35.0 PSF