Page 586 - Colony Catalog 8th Edition 2
P. 586

Circuit Seeker/Circuit Tracer
This tool features superior sensitivity and functionality providing for accurate tracing and locating. Tracing feedback is provided by both audible feedback and graphic display. Traces concealed wiring, locates junction boxes, and  nds breakers for live or open circuits. Can
be used on GFCI protected circuits, and does not affect sensitive electronic equipment on the circuit.
Buried Line Locator
Traces 20 feet underground and provides depth readings up to 15 feet. Both the transmitter and receiver have weather resistant housings for all-weather use. High brightness LEDs on the receiver are easy to read, even in the bright sunlight. Automatic signal boost makes it easy to trace lines, even those with very weak signals. The re- ceiver automatically locks out passive range when it detects a transmitter signal-reducing the chance of tracing other lines carrying weaker signals. Molded carrying case is included. Operates on eight (8) AA batteries. Manufactured by Greenlee.
Phase Sequence Indicator
Identi es L1, L2, L3 phases and indicates phase rotation before installation. Clockwise and counterclockwise indication via neon lamps. CAT III, 600V.
Item 12-1197
GFCI & Circuit Tester
Allows instant testing of GFCI receptacles
or GFCI
circuit breaker protected circuits. Checks 120VAC grounded
outlets for correct/incorrect wiring. LED Indicators signal correct wiring, open ground, open neutral, open hot, hot/ground reversed, and hot/neutral reversed. Cord length: 16" Weight: .05 lb. Manufactured by Greenlee.
TESTING & MEASUREMENT
COLONY
Operating Conditions
Temperature
0 to +50 oC (32 to 122 oF)
Altitude
2000 m (6500’) maximum
Pollution Degree
2
Indoor use only Transmitter
Measurement Category
Category III, 750V
Operating Voltage
0-750 V AC/DC
Live line
LED indicates voltage above 12 VAC or 5 VDC
Frequency
15.15 kHz
Low battery indicator
15.15 kHz
Batteries: Two AA batteries (NEDA 15A or IEC LR6)
Two AA batteries (NEDA 15A or IEC LR6)
Low Battery Indicator
Receiver
Range from Receiver to item with Signal
up to 20 ft (6 m) from circuit
Live Line Mode
Up to 20 ft (6 m) from circuit
Open Line Mode
Up to 10 ft. (3 m) with a metallic connection to ground.
1 to 3 ft. (.3 to .9 m) with a capacitive ground reference
Speci cations
Transmitter Operating Voltage
0-600 VAC, 0-0300 VDC
13mA (open line), 150mA (live or shorted line)
33.3 kHz
0°F to 120°F (-17°C to 50°C)
7.5" x 4" x 2.1"
12 Hz-24kHz
0°F to 120°F (-17°C to 50°C)
4.1" x 8.5" x 38" 1 lb. 2 oz.
Batteries See Page 101
Current
Frequency
Operating Temperature
Size
Receiver
Depth Range
Depth Resolution 0.1 ft. increments
Speci cations
Measurement Category
Cat II, 150V
Capacity
120VAC, 3-wire systems
Size
5-3/8” x 2-5/8” x 1-3/4”
0-15 ft.
Item
Model
Description
23-0014
5708
GFCI and Circuit Tester
Passive Trace Frequency
Operating Temperature
Size Weight
Polarity Cube Circuit Tester
Plug and test with ease. This unit is used to troubleshoot 120V AC grounded outlets. Designed to work with typical 3-wire NEMA 120 volt receptacles. Light sequence gives a visual indication of correct/incorrect wiring. Ergonomically designed to  t comfortably in the hand for
hours of testing. The GT-10GFI works with GFI outlets and con rms that the ground fault outlet is working properly. Independently tested to UL’s protocol 1436. Manufactured by Greenlee.
Item
Model
Description
23-0019
BLL- 200
Buried Line Locator
Item
Model #
Weight
12-1194
CS-8000
4.3 lbs.
Item
Model
Description
12-1140
GT-10
Circuit tester
23-0021
GT-10GFI
Circuit tester w/ GFI
TO ORDER CALL 800-698-0781 OR VISIT COLONYHARDWARE.COM