Page 35 - CERAMIC SHOWERS REVESTECH
P. 35
4_measure of the screen
The screen size must be at least equal to the length of the level shower tray.
5_special cases
Free space
In reforms or refurbishments, when the surface that is available for the installation is greater than the measures of our level shower tray, and there is free space, we place a xed area of tiling, with a slight slope of 0.5% to ll that space.
example::
We have a space of 87 cm. We install an 80 x 90 cm level shower tray and we add a 7 x 90 cm xed area
of tiling.
Overcoming an obstacle
When we have an obstacle on the surface of the installation, such as a column or any other obstacle, we place a xed areas of tiling with a slight slope of 0.5% around the edges of the shower oor.
example::
We have an obstructing We install the level shower tray and column. we place two xed areas of tiling.
37
87 cm
7cm 80cm
xed area
xed area
xed area