Page 139 - Designing for Zero Carbon-Volume 2_Case Studies of All-Electric Multifamily Residential Buildings
P. 139

  Edgewood Point, Long Beach
Number of Floors: 3
Gross Floor Area: 54,563 gsf
Fully Occupied: September 2023 Number of Units: 38 2BR Townhomes
EPILOGUE DESIGNING FOR ZERO CARBON, VOL. 2 New Market-Type Townhomes for Sale
Heating / Cooling System: Each townhome: Ducted-air split heat pump system with sepa- rate fan coil units for each thermostatically-controlled zone
DHW System: Indivdual heat pump water heater per townhome.
  Project Team
Client / Builder:
City Ventures
Architect:
WHA, Orinda, CA
MEP Engineer:
Southwest Group, Irvine, CA
Energy Modeling Con- sultant:
Southwest Group
Modeled EUI (Site)
14.4 kBtu/sf-year
Modeled Annual Energy Use:
230,763 kWh
Measured EUI (Site)
Not yet available
On-Site Renewable En- ergy System Installed
106.4 kW(DC) Solar PV
Measured On-Site Re- newable Energy Produc- tion
Not yet available
  Case Studies of All-Electric Multifamily Residential Buildings 125