Page 70 - SDC Catalog
P. 70

FIG. 1
WIRE DIAGRAM
55 SERIES ELECTRIC STRIKE
Power Connector Pigtail or
Monitoring Contact
FIG. 3
QUICK CONNECT POWER INPUT
(INCLUDED WITH STRIKES)
• 12VDC and 24VDC pigtails Included
• No need to cut and splice wires to configure voltage • Fewer wire nuts required
• Small connectors provide organized space saving wiring • Easy troubleshooting
QUICK CONNECT BUZZER (SEE ACCESSORIES)
• Buzzer in line between small connectors
• For failsecure strikes, audible tone indicate unlocked
• No need to cut and splice wires
• Reduces wire nut connections
• Small connectors provide organized space saving wiring • Easy troubleshooting
INSTRUCTIONS
24VDC
12VDC
FIG. 4
LCM
SPDT
LBM
SPDT
DBM
SPDT
50-RMB Buzzer
12 or 24 VDC Power Pig tail
HIGH SECURITY DOOR SECURE MONITORING: LBM/LCM Required
LCM & LBM wired in series indicates door is closed, latched and deadlocked or door is unlatched, open or unlocked.
FIG. 5
QUICK CONNECT BRIDGE RECTIFIER (SEE ACCESSORIES)
• Bridge rectifier in line between small connectors
• No need to cut and splice wires
• Eliminates 4 wire nut connections
• Small connectors provide organized space saving wiring • Easy troubleshooting
FIELD REVERSIBLE
HORIZONTAL ALIGNMENT ADJUSTMENT HORIZONTAL ALIGNMENT ADJUSTMENT FIG. 6 HORIZONTAL ALIGNMENT ADJUSTMENT
3A-Nominal Alignment: Loosen mounting screws. 3A-Nominal Alignment: Loosen mounting screws.
FIFEILEDLDRREEVVEERRSSIBIBLLE FAILSAFE / FAILSECURE
FIG. 2
FAFIALISLASAFFEE//FAFAILILSSEECURE Failsecure Mode: Factory supplied, Failsecure
Shift strikeSbhoifdt ystbrikeehibnoddtyhebefahcinedpltahte fhaocreizpolanteallhyo.rizontally. 3TAig-hNteonmminToaiugnlhtAtienlngigmsncomreuewntnsin.tg: Lsocroeswesn. mounting screws. Shift strike body
50-BR Bridge Rectifier
12 or 24 VAC Power Pig tail
Failsecure Mode: Factory supplied, Failsecure FaiFlsaaiflseeMcoudre:MReomdoev:eFcaocvteor,rypusuhpspoleiendoi,dFtoawilsaerdcure
Failsafe Mode: Remove cover, push solenoid toward end of strike as shown below.
b3eBh-iEnxdcethsseivfaecAelipglnamteenhtoIrsiszuoenst:ally. Tighten mounting screws. 3B-Excessive Alignment Issues:
Failsafe Mode: Remeonvdeocf sotvrikeer,apsusshhowsnoblenloowi.d toward end of strike as shown below.
Remove Cover
Remove Cover
FailsecureFailsecure Shown Shown
Failsafe Failsafe
3RBe-mEoxvceshsiimvefilAlelrigbanrmfreomntkIesespuer.s: Remove shim filler bar from keeper. Remove shim filler bar from keeper.
3A
3A 3B 3B
70
SDC SECURITY DOOR CONTROLS
■ WWW.SDCSECURITY.COM