Page 66 - FUXIN Catalog
P. 66
APPENDIX C
XTrim® WALL 970 Pro le Technical Data Sheet
Section Properties
Allowable Uniform Load (kN/m2)
ASD
Fy
(MPa)
Weight
(kg/m2)
Positive Bendings Negative Bendings
PANEL GAUGE(mm)
Ixe
(cm4)
Sxe
(cm3)
Maxo
(kN.m)
Ixe
(cm4)
Sxe
(cm3)
Maxo
(kN.m)
0.40
300
3.53
5.21
2.22
0.33
4.86
1.93
0.29
0.45
300
3.97
5.99
2.52
0.37
5.73
2.30
0.34
Thickness 0.40mm (kN/m2)
Span
Limite State
Length(mm)
600
700
800
900
1000
1100
1200
1300
Single
Serviceability
11.59
7.30
4.89
3.43
2.50
1.88
1.45
1.14
Ultimate
7.64
5.61
4.30
3.39
2.75
2.27
1.91
1.63
End
Serviceability
23.22
14.62
9.79
6.88
5.01
3.77
2.90
2.28
Ultimate
7.54
5.54
4.24
3.35
2.71
2.24
1.88
1.61
Internal
Serviceability
27.86
17.54
11.75
8.26
6.02
4.52
3.48
2.74
Ultimate
11.29
8.30
6.35
5.02
4.07
3.36
2.82
2.41
Allowable Uniform Load (kN/m2)
Thickness 0.45mm (kN/m2)
Span
Limite State
Length(mm)
600
700
800
900
1000
1100
1200
1300
Single
Serviceability
13.01
8.19
5.49
3.85
2.81
2.11
1.63
1.28
Ultimate
8.49
6.23
4.77
3.77
3.05
2.52
2.12
1.81
End
Serviceability
26.05
16.41
10.99
7.72
5.63
4.23
3.26
2.56
Ultimate
8.98
6.60
5.05
3.99
3.23
2.67
2.25
1.91
Internal
Serviceability
31.26
19.69
13.19
9.26
6.75
5.07
3.91
3.07
Ultimate
13.46
9.89
7.57
5.98
4.85
4.00
3.37
2.87
62