Page 40 - Demo
P. 40

 u2
150 10
0.10 0.20 0.30
Sleeve friction (fs) in MPa
Refusal ( 10 ton ) GWL dipped on site
0.40 0.50
-1
-2
-3
-4
-5
-6
-7
-8
-9
-10
-11
-12
-13
-14
-15
-16
-17
-18
-19
-20
-21
-22
-23
-24
c m2 c m2
3.8 3.4 3.2 3.0 2.7 3.4 3.9 4.7 4.8 5.1 5.0 5.1 5.6
0
Cone resistance (qc) in MPa
2 4 6 8 10 12 14 16 18 20
G.L.: 0.00 m
Friction ratio (Rf) in %
10 8 6 4 2
Tes t according A.S.T.M Standard D 5778-12 Project : Site Investigations
Location: Myrtle Dr - Omokoroa Position: 0, 0 RD
x
Inclination (I) in degr
Date : 27/10/2016
Cone no. : C10CFIIP.C13068
Project no. : 05OB4
CPTno. :03 1/14
1. 43
Depth in m to reference level ()



















































   38   39   40   41   42