Page 175 - Performance Health | Formerly Patterson Medical
P. 175
Iontophoresis Comparison
Iontophoresis Modalities
Patterson Medical
Performa Ve
Small
Medium
Large
N
8.8 cm
11.1 cm
18 cm
1.5 cc
2 cc
3 cc
4.0 ma (max)
4.0 mA (max)
4.0 mA (max)
80 mA-min
80 mA-min
80 mA-min
–
Fiber Matrix
Carbon
Smaller areas including fingers and Achilles tendon
Most areas including elbows, knees, wrists, feet and shoulders
Buffered Iontophoresis system. Viscosity enhancing agent to distribute current evenly. pH defining agent to optimize drug delivery. Comes in 3 sizes.
12
Travanti MedicalTM
IontoPatch®
80
STAT®
Extra Strength®
SP
Wireless
Y
Active Area
15.5 cm
12 cm
12 cm
8.1 cm
Approximate Fill Volume
1.3 ml
1.0 ml
1.0 ml
1.3 ml
Approximate Operating Current
0.1 mA
0.36 mA
0.25 mA
0.06 mA
Dosage
80 mA-min
80 mA-min
120 mA-min
40 mA-min
Wear Time
14 hrs avg
4 hrs avg
8 hrs avg
14 hrs avg
Skin Interface
Hypoallergenic, latex-free
Conductive Element
Screen-printed electrode
Screen-printed electrode with lithium battery
Screen-printed electrode with lithium battery
Screen-printed electrode
Treatment Area
Treats most areas including elbows, knees, wrists, feet, and shoulders
Treats smaller areas including fingers and Achilles tendon
Unique Feature
Published outcome study. 6 million clinical applications. No charging station or controller. Wrappable, compressible, weight bearing.
Qty per Box
6
ActivaTek
ActivaPatch
ActivaPatch ET
Trivarion
Chattanooga
Chattanooga
Small
Medium
Large
Butterfly
TransQFlex
TransQE Small
TransQE Medium
Companion 80
Small
Medium
Large
Wireless
Y
N
N
N
Y
N
N
N
Active Area
11.4 cm
7.9 cm
11.4 cm
20.2 cm
11.4 cm
11.2 cm
10.1 cm
13.4 cm
6.45 cm
7.2 cm
11.1 cm
16.3 cm
Approximate Fill Volume
2.0 cc
1.5cc
2.0 cc
3.5 cc
2.0 cc
2.5cc
1.5-2.0cc
2.5-3.0cc
1.1 cc
1.5 cc
2.5 cc
3.5 cc
Approximate Operating Current
6v
3v
4 mA
4 mA
4 mA
4 mA
4.0 mA (max)
4.0 mA (max)
1.5v
4.0 mA (max)
4.0 mA (max)
4.0 mA (max)
Dosage
40 mA-min or 80 mA-min
80 mA-min
Up to 80 mA - min
80 mA-min (max)
40 mA-min recommended
80 mA-min (max)
40 mA-min recommended
80 mA-min
80 mA-min (max)
40 mA-min recommended
Wear Time
1.15 hrs for 40 mA or 2.5 hrs for 80mA
12 hrs
–
–
–
24 hours
–
Skin Interface
Hypoallergenic
Fiber Matrix
Gel Sponge
Gel Sponge
Hypoallergenic adhesive
Gel Sponge
Conductive Element
Ag/AgCl-Neg Carbon-Positive
Silver-Silver Chloride
SSC
SSC
SSC
SSC
Treatment Area
Most areas including elbows, knees, wrists, feet and shoulders
Smaller areas including fingers and Achilles tendon (small size only) Most areas including elbows, knees,
wrists, feet and shoulders (all other sizes)
Most areas including elbows, knees, wrists, feet and shoulders
Most areas including elbows, knees, wrists, feet and shoulders
Most areas including elbows, knees, wrists, feet and shoulders
Smaller areas including fingers and Achilles tendon Most areas including
elbows, knees, wrists, feet and shoulders
Unique Feature
Fully integrated SMART POWER system, no dose controller needed no saline needed, interactive LED
Shunt resistor to deplete battery over 12 hrs. No dose controller needed, no saline needed.
Unique design conforms well to uneven treatment sites. Large ground electrode surface area lowers sensation and increases comfort.
Clover shape surrounds treatment area in two directions
Adhesive foam stretches and adheres well under stress. Circle shape
Battery on board, 24-hr. short circuit protection ensures drug delivery
SSC electrodes optimize the delivery of a broad range of drugs. EZ-Fill Window – peel away window provides easy filling and handling
Qty per Box
6
12
12
12
6
12
Illustration A
Matrix is uniformly impregnated with a Viscosity Enhancing Agent, pH Defining Agent and Buffering Agent
A Illustration B
Buffered Iontophoresis Electrodes Only from Patterson Medical
PerformaVe Buffered Iontophoresis Electrodes.
Revolutionary Design. The PerformaVe is a low-profile, buffered iontophoresis electrode designed to maximize drug delivery and speed patient recovery. It uses state-of-the-art technology to optimize the capabilities of a buffered ionto- phoresis system (Illustration A).
Uniform Distribution. A Viscosity Enhancing Agent distributes current more uniformly and deliver drug evenly (see Illustration B).
33% Higher Drug Delivery. Uses a pH de ning agent to adjust the drug pH to its ideal target.
Some buffered electrodes use granular buffers, leaving non- conducting air pockets that result in uneven distribution.
PerformaVe has a Viscosity Enhancing Agent that provides uniform current distribution and drug delivery.
5543-10 Small
5543-11 Medium $91.90 5543-12 Large $94.90
B
$89.85
PerformaVE Vial Venting System. 4547-27 $4.30
Order online. It’s click & easy: www.pattersonmedical.com
175
Modalities