Page 194 - Performance Health | Formerly Patterson Medical
P. 194

Modalities
Electrodes
E
PALS® Electrodes.
Designed for all FES and TENS applica- tions, these reusable electrodes combine
a patented, pliable, stainless steel knit fabric with a patented MultiStick® gel for maximum conformity and adhesion to even the most irregular surfaces.
Model Item No. A 5523-50
2350
B 5523-51
2351
C 5523-52
2352
D 5523-53
E 2354
F 5523-55
2355
G 5523-56
2356
H 5523-57
2357 I 2358
5523-58
HC
GA F
I
B
D GF
A
C
PALS® Foam Electrodes. Combines a patented knitted stainless steel fabric, comfortable foam outer layer and patented MultiStick® gel with an exclusive impedance compensation system.
Description Price
• If electrodes begin losing adhesion, gently rubbing one or
Description Price
Application and Removal
1.25” Round - 4/pk.
1.25” Round - 40/pk.
2” Round - 4/pk.
2” Round - 40/pk.
2.75” Round - 4/pk.
2.75” Round - 40/pk.
1.1” x 2.5” Butter y - 4/pk. 1.3” x 2” Rectangle - 40/pk. 2” Square - 4/pk.
2” Square - 40/pk.
2” x 3.5” Rectangle - 4/pk. 2” x 3.5” Rectangle - 40/pk. 2” x 5” Rectangle - 2/pk. 2” x 5” Rectangle - 20/pk. 3” x 4” Rectangle - 20/pk. 3” x 4” Rectangle - 2/pk.
$9.25 $88.15 $9.25 $92.70 $13.40 $127.80 $11.00 $98.50 $11.40 $99.50 $14.40 $135.30 $10.30 $98.50 $98.50 $11.00
Model Item No.
Skin must always be clean, dry and free from lotion.
A A939-81-3
Remove tBhe protective liner frAom9t3he9el-e8ctr5ode. Save lin2er”. Square - 4/pk. $10.65
B
D E
Modalities
2” Round - 4/pk. $9.25
two drops of water onto gel surface may extend usage. If
C A939-84 1.5” x 2.5” Oval - 4/pk. $10.40
Apply electrode securely to skin. Apply center first, then
smooth dDown to electrode edAge9s.39-86 2” x 4” Oval - 4/pk.
• DO NOT apply to broken skin. E A939-81-2 3” x 5” Oval - 2/pk.
Lift at the edge and peel to remove electrodes from skin.
$14.40
$11.20
F A939-81-4 2” x 3•.5” Rectangle - 4/pk.
Electrodes are intended for single person use only.
Replace tGhe electrode on the sAav9ed3p9ro-te8ct1ive-l5iner. Be s2ur”e x 5” Rectangle - 2/pk. $11.20
the electrode gel surface is placed onto the "ON" side. When not in use, replace electrodes in the original package
and store at room temperature.
brought to you by
NOTE: The life of the electrode varies depending on skin conditions, skin preparation, type of stimulation, storage and climate. Please read the stimulator device user’s manual thoroughly before use.
©2014 Axelgaard Mfg. Co., Ltd.
194
Call toll-free 1.800.323.5547 fax 1.800.547.4333
not, replace with new electrodes.
• DO NOT remove electrode by pulling on lead wire.
$15.10
ELECTRODE CARE
With Proper Care Your Electrodes Will Perform Better And Last Longer


































































































   192   193   194   195   196