Page 152 - Gas Detection Systems Training Manual
P. 152

Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
8618 Multi-Conductor - Audio, Control and Instrumentation Cable
General Description:
16 AWG stranded (19x29) tinned copper conductors, conductors cabled, polyethylene insulation, overall Beldfoil® shield (100% coverage), 18 AWG stranded tinned copper drain wire, PVC jacket.
For more Information please call
1-800-Belden1
Physical Characteristics (Overall)
Conductor
AWG:
Total Number of Conductors:
Insulation
Insulation Material:
Outer Shield
Outer Shield Material:
Outer Shield Drain Wire AWG:
Outer Jacket
Outer Jacket Material:
Overall Cable
Overall Cabling Color Code Chart:
Overall Nominal Diameter:
Mechanical Characteristics (Overall)
Operating Temperature Range:
UL Temperature Rating:
Bulk Cable Weight:
Max. Recommended Pulling Tension: Min. Bend Radius/Minor Axis:
3
# Conductors
AWG
Stranding
Conductor Material
3 16 19x29 TC - Tinned Copper
Insulation Material
Wall Thickness (in.)
PE - Polyethylene 0.032
Outer Shield Trade Name
Type
Outer Shield Material
Coverage (%)
Beldfoil® (Z-Fold®) Tape Aluminum Foil-Polyester Tape 100
AWG
Stranding
Drain Wire Conductor Material
18 16x30 TC - Tinned Copper
Outer Jacket Material
Nom. Wall Thickness (in.)
PVC-PolyvinylChloride .031
Number
Color
1 Black
2 Red
3 Clear
0.327 in.
-20°C To +80°C
80°C (UL AWM Style 20253) 60 lbs/1000 ft.
110 lbs.
3.500 in.
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: CL3
Page 1 of 3 04-30-2013