PLANNING
0Inside the bath or shower.
Must have a minimum rating of
IP67 and must be low voltage (12V
max). 1225cm above the bath or shower.
Minimum rating of IP44. If the fitting
is 240V a 30 ma RCD must also be
used to protect the circuit in this
zone. 2The area stretching to 60cm
outside the bath or shower and
60cm from water outlet of sink. An
IP rating of at least IP44 is required.
All Mirrors & Cabinets are compliant to BS:7671:2018, EN:60598-1:2015/A:2018, EN:60598-21:1989, EN62493:2015.
Our 2 Pin Shaver Sockets Conform to BS:4573”
Please note products with an Infrared sensor must be installed with a minimum of 200mm between the
sensor and any solid or reflective surface.
FIRST DIGIT INTRUSION PROTECTION SECOND DIGIT MOISTURE PROTECTION
0 No protection. 0 No protection
1 Protected against solid objects over 50mm,
e.g. accidental touch by hands. 1 Protected against vertically falling drops of
water, e.g. condensation.
2 Protected against solid objects over 12mm, e.g.
fingers. 2 Protected against direct sprays of water up
to 15 degrees from the vertical.
3 Protected against solid objects over 2mm,
e.g. tools and wires. 3 Protected against direct sprays of water up
to 60 degrees from the vertical.
4 Protected against solid objects over 1mm,
e.g. wires and nails. 4 Protected against water splashed from all
directions, limited ingress permitted.
5 Protected against dust limited ingress, no
harmful deposits. 5
Protected against low pressure jets of
water from all directions, limited ingress
permitted.
6 Total protected against dust. 6 Protected against strong jets of water, e.g.
on ship deck, limited ingress permitted.