 ELECTRICAL ZONES
   75cm
Zone 2
Zone 1
Zone 0
75cm Zone 2
Zone 2 75cm
Zone 1
Zone 0
60cm
       225cm Zone 2
Zone 2
Zone 2
Zone 2
             0 Inside the bath or shower. Must have a minimum rating of IP67 and
must be low voltage (12V max).
1 225cm above the bath or shower. Minimum rating of IP44. If the fitting is 240V a 30 ma RCD must also be used to protecrt the circuit in this zone.
2 The area stretching to 60cm outside the bath or shower and 60cm from
water outlet of sink. An IP rating of at least IP44 is required.
    FIRST DIGIT
  INTRUSION PROTECTION
  SECOND DIGIT
  MOISTURE PROTECTION
   0
 No protection.
   0
  No protection.
   1
 Protected against solid objects over 50mm, e.g. accidental touch by hands.
   1
  Protected against vertically falling drops of water, e.g. condensation.
   2
Protected against solid objects over 12mm, e.g. fingers.
  2
 Protected against direct sprays of water up to 15 degrees from the vertical.
   3
 Protected against solid objects over 2.5mm, e.g. tools & wires.
 3
  Protected against direct sprays of water up to 60 degrees from the vertical.
   4
  Protected against solid objects over 1mm, e.g. wires & nails.
  4
   Protected against water splashed from all directions, limited ingress permitted.
   5
Protected against dust limited ingress, no harmful deposits.
  5
 Protected against low pressure jets of water from all directions, limited ingress permitted.
   6
  Totally protected against dust.
  6
   Protected against strong jets of water, e.g. on ships deck, limited ingress permitted.
   All Mirrors & Cabinets are compliant to BS:7671:2018 , EN:60598-1:2015/A:2018, EN:60598-2-1:1989, EN62493:2015.
Our 2 Pin Shaver Sockets Conform to BS:4573”
Please note products with an Infrared sensor must be installed with a minimum of 200mm between the sensor and any solid or reflective surface.