P. 201

                 PLUMBING DIAGRAMS
The following diagrams have been developed to serve as a guideline for plumbing agricultural sprayers. Similar manual valves may be substituted for electric valves. However, the sequence in which these valves occur should remain the same. Note that one of the most common causes of premature valve failure is improper installation.
POSITIVE DISPLACEMENT PUMP
Piston, roller and diaphragm pumps are all types of positive displacement pumps. This means that pump output is proportional to speed and virtually independent of pressure. A key component in a positive displacement system is the pressure relief valve. Proper placement and sizing of the pressure relief valve is essential for safe and accurate operation of a positive displacement pump.
 Bypass Line
To Sprayer Control
            Bypass Line
D
Agitation Line
To Sprayer Control
A BI
  C
F
To Sprayer Control
G
C
Bypass Line
To Sprayer Control
G
C
J
H
  TWO-WAY PLUMBING DIAGRAM
(Positive Displacement) A – Tank Rinsing Nozzle B – Eductor Nozzle
C – Manual Shutoff Valve D – Throttling Valve
E – Electric Regulating Valve F – Pressure Relief Valve
G – Flowmeter
H – 2-Way Boom Control Manifold
I – Nozzle Bodies & Spray Tips
J – Line Strainer
E
Diaphragm Pump
J
 To Sprayer Control
               C
Bypass Line
D
A B
H
I
Agitation Line
To Sprayer Control
F
 THREE-WAY PLUMBING DIAGRAM
(Positive Displacement) A – Tank Rinsing Nozzle B – Eductor Nozzle
C – Manual Shutoff Valve D – Throttling Valve
E – Electric Regulating Valve F – Pressure Relief Valve
G – Flowmeter
H – 3-Way Boom Control Manifold
I – Nozzle Bodies & Spray Tips
J – Line Strainer
E
Diaphragm Pump
 TEEJET® TECHNOLOGIES
Distributed By: Sensor-1 • 202 Main Street, Princeton, KS 66078 • 1-800-SENSOR-1