Page 441 - Mainline Catalog 2023 Q1
P. 441

Model Details
ML82575 MIP/SWT
Min Case Qty Qty
5 5
ML82577 ML82579 ML82581
CPVC 55
PEXF1807 5 5
PEXF1960 5 5
Metal Fire Rated Washing Machine Boxes with Single Lever Valve with Hammer arrestors
Model
ML82591 ML82593
Details
MIP/SWT w/hammer arrestor PEX F1807 w/hammer arrestor
Min Case Qty Qty
5 5
5 5
Min Case Qty Qty
Model
ML82356 ML82358 ML82360 ML82362
PEX F1807 PEX F1960
Fire Rated Washing Machine Boxes with Quarter Turn Valves with Hammer arrestors
10 10
10 10
Min Case Qty Qty
10 10
10 10
10 10
10 10
Model
ML82372 ML82374 ML82376 ML82378
Details
MIP/SWT w/ hammer arrestor CPVC w/hammer arrestor PEX F1807 w/hammer arrestor PEX F1960 w/hammer arrestor
Metal Fire Rated Washing Machine Boxes with Single Lever Valve
• Manufactured from heavy duty steel with a white powder coated finish
• 2 Intumescent pad attached to inside and back of outlet box
• Simple installation - just nail or screw to stud
• No loose pieces to assemble allows quick installation
• Warnock Hersey certified
• 1 and 2 HR Rating - see design specification for exact rating
• Drains may be nominal 2” or larger PVC, ABS or metallic pipe
2
• Manufactured from heavy duty steel with a white powder coated finish
• 2 Intumescent pad attached to inside and back of outlet box
• Simple installation - just nail or screw to stud
• No loose pieces to assemble allows quick installation
• Warnock Hersey certified
• 1 and 2 HR Rating - see design specification for exact rating
• Drains may be nominal 2” or larger PVC, ABS or metallic pipe
2
Fire Rated Washing Machine Boxes with Quarter Turn Valves
CERTIFICATIONS
CERTIFICATIONS
• Made of High Temperature Resin
• Intumescent pad attached to back of outlet box
• Molded in test cap for testing of DWV drain system - Test cap will not fall down the drain
• Snap-on frame accommodates two 5/8” drywall
• Simple installation - Just nail or screw to stud
• Preloaded nails for right or left stud bay installation
CERTIFICATIONS
Details
MIP/SWT 10 10
CPVC 10 10
• Made of High Temperature Resin
• Intumescent pad attached to back of outlet box
• Molded in test cap for testing of DWV drain system - Test cap will not fall down the drain
• Snap-on frame accommodates two 5/8” drywall
• Simple installation - Just nail or screw to stud
• Preloaded nails for right or left stud bay installation
• Warnock Hersey Certified • 1hr & 2hr Rated