Page 535 - Mainline catalog 2023 Q2
P. 535
Model
ML42-25104-06
Min Case Qty Qty
1 1
Model
MLPD425118
Details
2 POLE
Min Case Qty Qty
1 1
Model
ML42-23116-08
Details
2 POLE
Min Case Qty Qty
1 1
Model
ML42-23116-07
Details
3 POLE
Min Case Qty Qty
1 1
Mainline Relay - Sealed Case SPDT-NO/NC 24VAC Coil
• HVAC Control Relay
• Sealed Case
• Contact Configuration: SPDT • Contact Bias: NO / NC
• Coil Voltage (VAC): 24
• Coil Frequency (Hz): 50/60
• FLA at 120V (A): 14
Details
Sealed Case
CERTIFICATIONS
• FLA at 230V (A): 8
• LRA at 120V (A): 84
• LRA at 230V (A): 48
• Resistive Rating at 277V (A): 25
• Terminal Connections: 1/4 in. Quick Connects
18
Mainline Heat Sequencing Relay - Flush Mount Plate - 24V DPST - NO 2 POLE 1-30/1-30
• HVAC Sequencing Relay
• Mounting: Flush Mount Plate w/Mounting Hole & Tab
• Heater Wattage/ Power Consumption: 24 VAC/.10A -.18A steady state/.35 - 1.0 amps peak for 0.8 sec.
• Heater Voltage (V): 24
• Contact Configuration: DPST - NO
• No. of Poles: 2
• On Timing - Pole 1 (seconds): 1-30
• On Timing - Pole 2 (seconds): 1-30
• Off Timing - Pole 1 (seconds): 40-110
• Off Timing - Pole 2 (seconds): 40-110
• Connections: 1/4 in. Quick Connects
• Motor FLA at 120V (A): Pole 1: 14 Pole 2: 14
• Motor LRA at 120V (A): Pole 1: 72 Pole 2: 72
• Pilot Duty Rating at 120V (VA): Pole 1: 125 Pole 2: 125 • Resistive Rating at 120V (A): Pole 1: 25 Pole 2: 25
• Motor FLA at 230V (A): Pole 1: 7 Pole 2: 7
• Motor LRA at 230V (A): Pole 1: 42 Pole 2: 42
• Pilot Duty Rating at 230V (VA): Pole 1: 125 Pole 2: 125 • Resistive Rating at 230V (A): Pole 1: 25 Pole 2: 25
• Motor FLA at 460V (A): Pole 1: 4 Pole 2: 4
• Motor LRA at 460V (A): Pole 1: 24 Pole 2: 24
• Pilot Duty Rating at 460V (VA): Pole 1: 125 Pole 2: 125 • Resistive Rating at 460V (A): Pole 1: 12.5 Pole 2: 12.5
• HVAC Sequencing Relay
• Mounting: Angle Bracket WITH Two Mounting Holes
• Heater Wattage/ Power Consumption: 24 VAC / 0.2A steady state / 0.55A maximum
• Heater Voltage (V): 24
• Contact Configuration: DPST - NO
• No. of Poles: 2
• On Timing - Pole 1 (seconds): 10-30
• On Timing - Pole 2 (seconds): 10-30
• Off Timing - Pole 1 (seconds): 30-60
• Off Timing - Pole 2 (seconds): 30-60
• Connections: 1/4 in. Quick Connects
• Motor FLA at 120V (A): Pole 1: 14 Pole 2: 14
• Motor LRA at 120V (A): Pole 1: 72 Pole 2: 72
• Pilot Duty Rating at 120V (VA): Pole 1: 125 Pole 2: 125 • Resistive Rating at 120V (A): Pole 1: 25 Pole 2: 25
• Motor FLA at 230V (A): Pole 1: 7 Pole 2: 7
• Motor LRA at 230V (A): Pole 1: 42 Pole 2: 42
• Pilot Duty Rating at 230V (VA): Pole 1: 125 Pole 2: 125 • Resistive Rating at 230V (A): Pole 1: 25 Pole 2: 25
• Motor FLA at 460V (A): Pole 1: 3 Pole 2: 3
• Motor LRA at 460V (A): Pole 1: 18 Pole 2: 18
• Pilot Duty Rating at 460V (VA): Pole 1: 125 Pole 2: 125 • Resistive Rating at 460V (A): Pole 1: 12.5 Pole 2: 12.5
• HVAC Sequencing Relay
• Mounting: Angle Bracket WITH Two Mounting Holes
• Heater Wattage/ Power Consumption: 24 VAC / 0.2A steady state / 0.55A maximum
• Heater Voltage (V): 24
• Contact Configuration: TPST - NO
• No. of Poles: 3
• On Timing - Pole 1 (seconds): 10-30
• On Timing - Pole 2 (seconds): 10-30
• On Timing - Pole 3 (seconds): 10-30
• Off Timing - Pole 1 (seconds): 90-150
• Off Timing - Pole 2 (seconds): 30-60
• Off Timing - Pole 3 (seconds): 30-60
• Connections: 1/4 in. Quick Connects
• Motor FLA at 120V (A): Pole 1: 7 Pole 2: 7 Pole 3: 7
• Motor LRA at 120V (A): Pole 1: 42 Pole 2: 42 Pole 3: 42
• Pilot Duty Rating at 120V (VA): Pole 1: 125 Pole 2: 125 Pole 3: 125 • Resistive Rating at 120V (A): Pole 1: 25 Pole 2: 25 Pole 3: 25
• Motor FLA at 230V (A): Pole 1: 7 Pole 2: 7 Pole 3: 7
• Motor LRA at 230V (A): Pole 1: 42 Pole 2: 42 Pole 3: 42
• Pilot Duty Rating at 230V (VA): Pole 1: 125 Pole 2: 125 Pole 3: 125 • Resistive Rating at 230V (A): Pole 1: 25 Pole 2: 25 Pole 3: 25
• Motor FLA at 460V (A): Pole 1: 3 Pole 2: 3 Pole 3: 3
• Motor LRA at 460V (A): Pole 1: 18 Pole 2: 18 Pole 3: 18
• Pilot Duty Rating at 460V (VA): Pole 1: 125 Pole 2: 125 Pole 3: 125 • Resistive Rating at 460V (A): Pole 1: 12.5 Pole 2: 12.5 Pole 3: 12.5
CERTIFICATIONS
18
Mainline Heat Sequencing Relay - Angle Bracket w/2 Mounting Holes - 24V DPST - NO 2 POLE 10-40/30-60
CERTIFICATIONS
18
Mainline Heat Sequencing Relay - Angle Bracket w/2 Mounting Holes - 24V TPST - NO 3 POLE 10-30/10-30/10-30
CERTIFICATIONS
18