Page 28 - Reeley 2019 Catalogue
P. 28

  27 Drawings are actual size and are for idSeInZtEifSicaAtRioEnSpHuOrpWosNesINonMlyILLIMEPTleRaEseSsee our website for up to date pricing
     Version D:
With an integrated metal insert to replace version B.
T Type - Certified According to EN81-1/2
Version C:
With a square steel fixing plate, four corner fixing holes and one central fixing hole
PIT BUFFERS
   Load limits according to EN 81
  TUV-Code : 0032 Buffer size
    T1
   T2
   T3
   T4
   T5
   Diameter (D) Height (H) Compression
  80 80 72
  100 80 72
  125 80 72
  165 80 72
  220 80 72
    Nominal Velocity (m/s)
  Load range
 Load (kg)
   0.4
  max. min.
    1450 153
   1886 153
   2800 200
   6170 310
   9200 465
   0.63
max. min.
  1300 153
 1137 153
 2240 300
 3000 379
 7100 1000
   1
  max. min.
    500 233
   800 290
   1300 300
   2450 568
   6000 1344
 The following pages show all our stock items, but we can supply any of the standard configurations within 7-10 days.