P. 28
27 Drawings are actual size and are for idSeInZtEifSicaAtRioEnSpHuOrpWosNesINonMlyILLIMEPTleRaEseSsee our website for up to date pricing
Version D:
With an integrated metal insert to replace version B.
T Type - Certified According to EN81-1/2
Version C:
With a square steel fixing plate, four corner fixing holes and one central fixing hole
PIT BUFFERS
Load limits according to EN 81
TUV-Code : 0032 Buffer size
T1
T2
T3
T4
T5
Diameter (D) Height (H) Compression
80 80 72
100 80 72
125 80 72
165 80 72
220 80 72
Nominal Velocity (m/s)
Load range
Load (kg)
0.4
max. min.
1450 153
1886 153
2800 200
6170 310
9200 465
0.63
max. min.
1300 153
1137 153
2240 300
3000 379
7100 1000
1
max. min.
500 233
800 290
1300 300
2450 568
6000 1344
The following pages show all our stock items, but we can supply any of the standard configurations within 7-10 days.