Page 474 - 2020-2021 Catalogue
P. 474

BATTERY CHARGERS
P12 BATTERY CHARGERS
The P12 Battery Charger is a four stage, three output, dry mount device designed for use in harsh environments where reliability, ease of use, and high performance are of primary importance. Backed by a 5-year warranty and technical phone support, the P12 Battery Charger is designed, assembled, and tested at Blue Sea Systems’ headquarters.
Designed to meet these three core company philosophies:
1. Reliability
• Rugged, finned aluminum case • Universal line voltage 90-265V AC, 50/60 Hz • PreFloatTM stage prevents over charging by allowing each battery to end absorption stage individually • Power factor corrected for efficient use of AC
2. Ease of Use
• Intuitive diagnostic screens • User selectable charge profiles for Lead Acid, Gel, AGM, TPPL, & other battery types • Provides charging for up to three battery banks • Large, bright display • Multi-language: English, French, German, Italian, Spanish • Charge coordination with Blue Sea Systems Automatic Charging Relays (ACR)
controls ACR state ensuring proper float stage for each battery.
3. Support and Safety
• Factory technical support • 5 year warranty • Ignition protected • AC over & under voltage shut down
& automatic restart • Over and under battery temperature protection • DC over voltage and reverse polarity protection • Surge & short circuit protection
Regulatory:
Designed and constructed for compliance to UL-1236 Marine, CSA 22.2 No. 107.2, and ABYC A-31 standards. Ignition Protection
per ISO 8846, and SAE J1171. Meets FCC Part 15, Class B requirements.
738-75320
Specifications:
Total Output Current Input AC Current
Recommended Battery Bank Sizes*
Nominal Output Voltage Ignition Protected Output Connections Universal AC Input Voltage AC Input Frequency Range Typical Float Voltage Maximum Available Voltage Output Voltage Accuracy Operating Temperature Storage Temperature Warranty
Battery Types**
7531
25A 4.5A @ 100V AC 2.25A @ 200V AC 160Ah Minimum 60Ah Minimum 330Ah Maximum
12V DC Yes 3 positive, 1 negative 90V-265V AC 45-65 Hz 13.5V DC 16.0V DC 0.05V DC -20˚C (-4˚F) to 70˚C (58˚F) -30˚C (-22˚F) to 80˚C (176˚F) 5 Year Flooded Lead Acid, Gel, AGM, TPPL
7532
40A 7.5A @ 100V AC 3.75A @ 200V AC 60Ah Minimum 60Ah Minimum 440Ah Maximum
12V DC Yes 3 positive, 1 negative 90V-265V AC 45-65 Hz 13.5V DC 16.0V DC 0.05V DC -20˚C (-4˚F) to 70˚C (58˚F) -30˚C (-22˚F) to 80˚C (176˚F) 5 Year Flooded Lead Acid, Gel, AGM, TPPL
ORDER NO.
738-75310
738-75320
Mfr. No.
7531
7532
Voltage	Amps
12V DC	25A
12V DC	40A
* Battery bank sizes are recommended for optimal charging efficiency-see bluesea.com/P12 for details ** Consult battery manufacturer specifications for other battery types to avoid damage Do not mix battery chemistries
For more information see: www.bluesea.com
448