TRASFORMATORE DI CORRENTE TIPO AD UN NUCLEO
24 kV
TRASFORMATORE DI CORRENTE TIPO AD UN NUCLEO
24 kV
SINGLE CORE CURRENT TRANSFORMER
SINGLE CORE CURRENT TRANSFORMER
Modello
CARATTERISTICHE STANDARD cACRAARTATTETREISRTIIScThIECHSETASNTDAANRDDARD
Modello
CTA S-1
- Isolamento a secco in resina - Funzionamento all’interno
Type
CTA S-1
- Isolamento a secco in resina - Funzionamento all’interno - Installazione esposta
Type
- Installazione esposta
- Installazione anche in clima tropicale
- Installazione anche in clima tropicale
- Tensione di riferimento per l’isolamento 24 kV
- Tensione di riferimento per l’isolamento 24 kV
- Tensione di prova a freq. industriale e ad impulso 50/125 kV
- Tensione di prova a freq. industriale e ad impulso 50/125 kV - Frequenza 50 Hz oppure 60 Hz
- Frequenza 50 Hz oppure 60 Hz
- Corrente nominale secondaria 5 A oppure 1 A
- Corrente nominale secondaria 5 A oppure 1 A
- Corrente nominale termica di c.to c.to (Ith) 100 Ipn /1”- max 40 kA
- Corrente nominale termica di c.to c.to (Ith) 100 Ipn /1”- max 40 kA - Corrente nominale dinamica (Idyn) 2,5 Ith
- Corrente nominale dinamica (Idyn) 2,5 Ith
- Costruzione in accordo alle norme IEC 61869-1/2
- Costruzione in accordo alle norme IEC 61869-1/2 - Coprimorsetti sigillabile sul secondario
- Coprimorsetti sigillabile sul secondario
ESECUZIONI REALIZZABILI A RICHIESTA ESESCUEcZIUOzNIOINRI ERAELAIlZIzZzAABbIILlI AARIRcIhCIHEISETASTA
- Corrente nominale secondaria diversa da 1 A e 5 A
- Corrente nominale secondaria diversa da 1 A e 5 A - Costruzione in accordo alle norme VDE ,BS ,ANSI
- Costruzione in accordo alle norme VDE ,BS ,ANSI - Rapporti e prestazioni diversi da quelli indicati
- Rapporti e prestazioni diversi da quelli indicati
- Corrente nominale di c.to c.to superiori a 100 Ipn/1” max 40 kA
- Corrente nominale di c.to c.to superiori a 100 Ipn/1” max 40 kA - Presa capacitiva
FEATURES STANDARD FEAFTEUARTEUSRESTASNTDAANDRADRD
- Presa capacitiva
- Dry insulation in resin – Indoor installation - Dry insulation in resin – Indoor installation
- Exposed installation - Exposed installation
- Indoor installation also in tropics - Indoor installation also in tropics
- Highest system voltage up to 24 kV - Highest system voltage up to 24 kV
- Test voltage (1’/50Hz) and impulse voltage 50/125 kV - Test voltage (1’/50Hz) and impulse voltage 50/125 kV
- Frequency 50 Hz or 60 Hz - Frequency 50 Hz or 60 Hz
- Normal secondary rated 5 A or 1 A - Normal secondary rated 5 A or 1 A
- Rated short-time thermal current (Ith) 100 Ipn/1” max 40 kA - Rated short-time thermal current (Ith) 100 Ipn/1” max 40 kA
- Rated dynamic current (Idyn) 2,5 Ith - Rated dynamic current (Idyn) 2,5 Ith
- Transformers according to IEC 61869-1/2 - Transformers according to IEC 61869-1/2
- Sealable protection on the secondary - Sealable protection on the secondary
SPECIAL EXECUTIONS ON REQUEST SPEECCIIALl ExXECUTIOONSOONRREEqQUEST
- Rated secondary current different from 1 A and 5 A - Rated secondary current different from 1 A and 5 A
 Peso kg 17,5 circa – Weight kg 17,5 abt.
 Peso kg 17,5 circa – Weight kg 17,5 abt.
Dimensioni d’ingombro ( mm ) - Outline dimensions ( mm ) Fig.1Dimensioni d’ingombro ( mm ) - Outline dimensions ( mm )
- Rated short-time thermal current different from 100 Ipn/1” max 40 kA - Rated short-time thermal current different from 100 Ipn/1” max 40 kA
- Transformers according to VDE ,BS ,ANSI - Transformers according to VDE ,BS ,ANSI
- Different burdens from the ones indicated - Different burdens from the ones indicated
- Capacitive voltage tap - Capacitive voltage tap
Fig.1
Rating plate earthing screw Rating plate earthing screw
sez. B - pag. 7
sseezz..BB--ppaagg..37


































































































   34   35   36   37   38