Page 1 - Roofseal Catalogue
P. 1

ROOFSEAL


                                                                                 APP Modified Waterproofing  membrane






                             DESCRIPTION                                  QUALITY CONTROL
                             BITUMAT  ROOFSEAL  is a pre-fabricated  APP  In addition to stringent regular tests by
                             modified bitumen membrane designed for       BITUMAT laboratory, our products  are tested
                             economy and easy applications.               periodically  by Independent  laboratories.

                             ROOFSEAL  "P"  is reinforced  with 180 gsm  non
                             -woven  polyester fabric, whereas  ROOFSEAL
                             "G" is reinforced  with a glasfiber mat. The re-  INSTALLATION TOOLS REQUIRED
                             inforcement  is impregnated  and coated on both
                             sides with polymer modified bitumen.         Gas torch, Knife, Trowel, Measuring  tape,
                                                                          Marking string, Gloves.
                             USES
                                                                          APPLICATION
                             BITUMAT ROOFSEAL  membrane  is idealfor  a
                             wide range of waterproofing  applications    BITUMAT ROOFSEAL is installed  by torch
                             including roofs, basements, tunnels, car parks  welding  method.
                             and reservoirs.
                                                                          Peripheries  and protrusions  are sealed
                                                                          accord ing to specifications.
                             OUTSTANDING  FEATURES

                             o Total impermeability                       COVERAGE RATE (Approx.)
                             o Good  bondability  & seam integrity
                             o Stability  at high temperature             (Rate may very as site requirement)
                             o Good flexibility
                             o Compatible  with all normal roofing  and   Flat areas :  1.15 M'/M' per layer with 10 cms.
                               building  Components                                   Side laps and 15 cms.
                                                                                      End laos.


                             GENERAL DATA
                             Nominal  Roll Length  10 Mtrs.               TORCHING GUIDELINES
                             Nominal  Rollwidth  1M
                             Nominal Thickness  3,4,5, MM                 The underside of the membrane should  be
                             Re-inforcement     Non-woven  polyester/     torched  just enough  to superficially  melt the
                                                Glasfibre mat             bitumen.  Excessive heating may damage  re-
                                                                          inforcement.

                             PACKAGING                                    Overlaps  should  be re-heated  from the top and
                                                                          resealed with a trowelto ensure seam integrity.
                             o  3MM -  28 rolls / pallet
                             o  4mm  -  23 rolls / pallet                 For details  of installation methods  and flashing
                                                                          requirements,  consult the relevant BITUMAT
                                                                          sysfem design and lnstallation  Manual.
                             FINISHES
                             BITUMAT  ROOFSEAL  is available  in two basic
                             finishes:
                             o  Black smooth  finish with polyethylene
                               surfaces  for covered  applications.
                             o  Granule  surfacing  for exposed
                               applications.
   1   2