 Material Proper es Of High Performance Precision Strip Steel Jonas Nilsson |R&D Mgr. Precision Strip | Sandvik Materials Technology | SE
11/26/17
      FATIGUE
 7
 FATIGUE
•  When exposed to a dynamic load a steel may fracture at a stress significantly lower than the tensile strength
•  Wöhler diagrams gives information on stresses allowed for a certain grade and dimension