 David Allen | Emeritus Professor | Cranfield University | UK Photochemical Machining of Aerospace Materials
5/31/18
   Ferric chloride etchants for aluminium (5)
There was a need to investigate other safer additives to dilute ferric chloride.
Lightwala has investigated:
•  Orthophosphoric acid (H3PO4) •  Polyphosphoric acid
•  Nitric acid (HNO3)
•  Hydrochloric acid (HCl)
All brought a marked improvement in etch rate. Etching for 10 min gave higher etch rates and smoother finish than etching for 5 min, thereby illustrating the protective effect of the passivating layer.
   Regeneration of aluminium etchants
    Etchant
Regeneration system
Ferric chloride
Chlorine gas
(lowering the cost by at least a factor > 2 according to Wible)
Sodium hydroxide
Secondary crystallisation of Al(OH)3 from NaAlO2 to release sodium hydroxide
Alkaline potassium ferricyanide
Electrolysis using a semi- permeable membrane to separate anode from cathode.
Ozonolysis.