Page 16 - Parkside Brochure_TexasCapitalBank
P. 16

practical.

           mindful.
           cutting edge.                                                                                                                              Constant infusion of fresh                                                     Exhaust
                                                                                                                                                                                                                                      Exhaust Air
                                                                                                                                                      air that exceeds ASHRAE
                                                                                                                                                                                                                                     Air
           Engineered with a heightened                                                                                                               recommendations
           sense of responsibility                                                                                                                                                                 100% Air Side

                                                                                                                                                                                                   Economizer                        Fresh
                                                                                                                                                                                                                                      Fresh Outside Air
                                                                                                                                                                                                                                     Outside
                                                                                                                                                                                                         AHU                         Air



                                                                                                                                                      All air is limited to serving                                                  Exhaust
                                                                                                                                                                                                                                      Exhaust Air
                                                                                                                                                      one floor and does not                                                          Air
                                                                                                                                                      mix with other floors
                                                                                                                                                                                                       MERV 13
                                                                                                                                                                                                        Filters
                                                                                                                                                                                                                                     Fresh
                                                                                                                                                                                                                                      Fresh Outside Air
                                                                                                                                                                                                                                     Outside
                                                                                                                                                                                                         AHU                         Air



                                                                                                                                                         Opportunity for low                                                         Exhaust
                                                                                                                                                                                                                                      Exhaust Air
                                                                                                                                                         air returns for faster                                                      Air
                                                                                                                                                         circulation of densely                       Option for
                                                                                                                                                         occupied spaces                              Ultraviolet

                                                                                                                                                                                                      or Bi-Polar
                                                                                                                                                                                                      Ionization                     Fresh
                                                                                                                                                                                                                                      Fresh Outside Air
                                                                                                                                                                                                                                     Outside
                                                                                                                                                                                                         AHU                         Air

                                                                                              Healthy, Sustainable, Green.
                                                                                                                                                                                                               Peace of Mind



           State-of-the-art technology helps Parkside Uptown achieve a new level of safety and   part of Parkside
           security. Touchless controls on primary doors, plumbing fixtures and elevator panels   Uptown’s commitment
           create a more hygienic environment. To encourage social distancing, destination
           elevators optimize the number of passengers per trip and limit lobby wait times.  to wellness

           For even greater peace of mind, advanced air circulation and filtration methods ensure the highest possible air quality. Each floor
           employs its own 100% outside air economizer to provide a constant infusion of fresh air that exceeds ASHRAE recommendations.
           Further,  all  air  recirculation  occurs  on  a  floor-by-floor  basis  resulting  in  no  possible  cross-contamination  of  air  between  floors.
           Meanwhile, airborne bacteria and allergens are e†ciently removed by the same MERV 13 filters trusted by hospitals. Tenants are also
           a‰orded an infection control mode of operation, which accelerates room air changes to every few minutes.
           You may even choose to add low air returns to hasten particulate removal from densely occupied spaces and upgrade to an ultraviolet
           or bipolar ionization air filtration system. It’s all part of Parkside Uptown’s commitment to wellness.