Drilling, Milling, Tapping and Threading
®
Mebux thread inserts
Application - Metric thread
Step 1:
Drill out the damaged thread with the Mebux
HSS drill bit (C) to the bottom. Pay attention to
the direction of the hole
Step 2:
Use the Mebux fit milling cutter (D) to
countersink the hole until the depth stop is
resting on the workpiece.
A = B =
Step 3:
Screw-in tool Thread cutter
The thread cutter (B) can now be used to cut a
new thread. Straight guidance in the bore hole
is important. Turn out the thread cutter (B) once
the full drilling depth has been reached and
blow out the chips.
Step 4:
Noticeable resistance occurs when the threa-
ded sleeve has been fully inserted into the
thread using the lubricated turning tool (A).
Continue to turn the tool until the turning-in re-
sistance drops perceptibly. Only this method
ensures that the sleeve is pressed into the thre-
ads of the work piece.
Sleeve Sleeve
turned in pressed in
C = D =
Drill bit Seat burr, tap borer
Technical data subject to change.