Page 93 - Icon Ridge Working Gear
P. 93

Working Security


                 approved for use when handling foodstuffs



                 EN 60903 insulating protective gloves for
                 work under electrical voltage


          EN 455 medical gloves for single use





                 ESD (electrostatic discharge) = protection
                 from electrostatic discharge
























                EN 388 Protection from Mechanical Risks             EN 374/1 Protection from Fluids and Slight
                                                                    Chemical Hazards
           Test Criteria           Assessment Possibility      Test Criteria            Assessment Possibility
           Abrasion Resistance     0 – 4                       Penetration Test         passed / failed
                                                               (Water Leak Test)
           Cut Resistance          0 – 5
                                                              This pictogram is used for fluid-tight gloves, that does not meet the
           Tear Resistance         0 – 4
                                                              above-mentioned requirements
           Puncture Resistance     0 – 4

                EN 511 Protection from Cold                         EN 374/2 Protection from Micro-Organisms



           Test Criteria           Assessment Possibility      Test Criteria            Assessment Possibility
           Convective Cold         0 – 4                       Penetration Test         passed / failed
                                                               (Air / Water Leak Test)
           Contact Cold            0 – 4
           Water Tightness         0 – 1


                EN 407 Protection from Thermal Risks (Heat           EN 374/3 Protection from Chemical Hazards
                or Fire)

           Test Criteria           Assessment Possibility      Test Criteria            Assessment Possibility
           Burning Behaviour       0 – 4                       Penetration Test         passed / failed
                                                               (Air / Water Leak Test)
           Contact Heat            0 – 4
                                                                                        Breakthrough Time
                                                               Permeation Test
           Convective Heat         0 – 3                                                (Performane Stage 0 - 6)
           Radiated Heat           0 – 4
                                                              This pictogram is used for fluid-tight gloves that have a breakthrough
           Exposure to Small Spurted   0 – 4                  time of > 30min. for at least 3 chemicals from the list of "Code Letters":
           Molten                                             (AKL represent the code letters for 3 of these chemicals for which the
                                                              gloves have achieved a breakthrough time > 30 min.))
           Metal Particles         0 – 4

       Technical data subject to change.