Temperature and ambient conditions monitoring \ Ambient monitoring measuring instruments
Temperature/humidity measuring instrument
Application: Large digits for clear view of measured values
For measuring indoor climates
Delivery:
Execution: Battery (1x 9 V block battery, type 6 LR 61)
Running display
Max-hold display Technical data:
Min-hold display Min./max. temperature measuring range: -20 to
60 °C
Energy-saving Auto-OFF function Temperature error limit: 0.5 °C
Advantage: Min./max. humidity (rF) of measuring range: 0-99
%
Handy device size and easy one-hand operation Humidity (rF) error limit/conditions: 5 % / from 20
Automatic display illumination with brightness to 70%
sensor Humidity (rF) error limit, residual area: 7 %
46210... Ident. No. 010
●
Prod. Gr. 456
Flow meter (anemometer)
Application: Automatic display illumination with brightness
For simple measurements of air-conditioning venti- sensor
lation systems. Large digits for clear view of measured values
Execution: Delivery:
Running display Battery (1x 9 V block battery, type 6 LR 61)
Max-hold display
AVG display (average value) Technical data:
Switch between units of display: m/s, km/h, ft/ Min./max. current of measuring range: 0.4-25 m/s
Digit increment, current: 0.01 m/s
min., MPH, knots Current error limit (+/-): 0.45 m/s
Energy-saving Auto-OFF function Min./max. working temperature: 0 to 40 °C
Advantage:
Handy device size and easy one-hand operation
46210... Ident. No. 020
●
Prod. Gr. 456
Light intensity measuring instrument (luxmeter)
Application: Automatic display illumination with brightness
For monitoring lighting conditions in workplaces, sensor
warehouses, industrial buildings and residential Large digits for clear view of measured values
buildings.
Delivery:
Execution: Battery (1x 9 V block battery, type 6 LR 61)
Automatic zero point calibration
Max-hold display Technical data:
Switch between units of display: LUX Fc Digit increment, illumination: 0.01 lx
Illumination error limit (+/-): 5 lx
Energy-saving Auto-OFF function Min./max. working temperature: 0 to 40 °C
Advantage:
Handy device size and easy one-hand operation
46210... Ident. No. 030
●
Prod. Gr. 456
Sound level measuring instrument
Application: Automatic display illumination with brightness
For monitoring permissible noise pollution levels, sensor
e.g. in workplaces. Large digits for clear view of measured values
Execution: Delivery:
Running display Battery (1x 9 V block battery, type 6 LR 61)
Max-hold display
Min-hold display Technical data:
Energy-saving Auto-OFF function Min./max. sound-pressure-level measuring range:
40-130 dB
Advantage: Digit increment, sound-pressure level: 0.1 dB
Handy device size and easy one-hand operation Sound-pressure-level error limit (+/-): 3.5 dB
Min./max. working temperature: 0 to 40 °C
46210... Ident. No. 040
●
Prod. Gr. 456
Source: Hahn+Kolb Werkzeuge GmbH
Technical data subject to change. www.iconridge.com 1099