Page 1 - ps SIGNAL AND TELECOM
P. 1

SIGNAL AND TELECOM

              I.   General

              HYB  division  has  MACLS  with  LED Signals.  All  the  stations  are  provided  with  Integrated
              Power Supply (IPS) and Dataloggers networked to Divisional and Zonal HQrs. On Telecom
              side the division has 100% 6 Quad underground cables for communication.  OFC provided
              in the entire division except MJF BP – MLY GC section.

             II.   Key information of S&T department

                  Type of Signaling

                    MACLS with Panel and EI                                  :      57(PI-43 & EI-14)
                   a.  Standard III®                                         :      06
                       (TMX,SHNR,BABR,UR,BDVL&FM)
                   b.  Standard II ®                                         :      50
                   c.  Standard I                                            :      01 (BDHN)
                  Type of block working

                   Absolute Block Sections                                   :      50

                   a.  Single line Token less Block Sections                 :      41
                   b.  Single line UFSBI with BPAC                           :      05(MED-MOB,GLY-JCL,BVO-DHNE
                                                                                                                                                                         GWD-PASR& PASR-RC)
                   c.  Double line UFSBI with BPAC                           :      04(UR-TMX-SHNR-BABR-GLY)

                   Automatic Block Sections                                  :      09(MED-GDPL-BMO-CVB-MJF-
                   STPD‟B
                                                                                                                                                                             STPD‟A-KCG-FM-BDVL-UR)

                  L.C. Gates

                   a.  Total Manned Gates                                    :         140
                   b.  Total Interlocked gates                               :      79
                   c.  Mid-Section Interlocked gates                         :      39
                   d.  Station Section Interlocked Gates                     :      40
                   e.  Sliding Type Boom at Interlocked gates                :      69(Tfc -39& Engg-30)
                   f.  Electrically Operated Lifting Barriers                :          28 (Tfc-16& Engg-12)


                  Power Supply Arrangement

                   a.  Full IPS                                              :      57
                   b.  Mini IPS                                              :      45
                   c.  Solar Panels at Stations                              :      11
                   d.  Solar Panels at LC gates                              :      33

                  Data Loggers

                   a.  Stations/Cabin                                        :      58
                   b.  LC gates/ Auto Sections/Huts                          :      74 (RTUs)