Page 1 - CRS - S & T
P. 1

D) Signal & Telecommunication



              I.   General


              HYB  division  has  MACLS  with  LED  Signals.  All  the  stations  are  provided  with  Integrated
             Power Supply (IPS) and Dataloggers networked to Divisional and Zonal HQrs. On Telecom
             side the division has 100% 6 Quad underground cables for communication.  OFC provided in
             the entire division except MJF BP – MLY GC section.

             II.   Key information of S&T department

                  Type of Signaling

                   MACLS with Panel and EI                                 :      57(PI-43 & EI-14)
                   a.  Standard III®                                       :      06
                      (TMX,SHNR,BABR,UR,BDVL&FM)
                   b.  Standard II ®                                       :      50
                   c.  Standard I                                          :      01 (BDHN)
                  Type of block working

                   Absolute Block Sections                                 :      50

                   a.  Single line Token less Block Sections               :      41
                   b.  Single line UFSBI with BPAC                         :      05(MED-MOB,GLY-JCL,BVO-DHNE
                                                                                                                                                                        GWD-PASR& PASR-RC)
                   c.  Double line UFSBI with BPAC                         :      04(UR-TMX-SHNR-BABR-GLY)

                   Automatic Block Sections                                :      09(MED-GDPL-BMO-CVB-MJF-STPD’B
                                                                                                                                                                             STPD’A-KCG-FM-BDVL-UR)

                  L.C. Gates

                   a.  Total Manned Gates                                  :         140
                   b.  Total Interlocked gates                             :      79
                   c.  Mid-Section Interlocked gates                       :      39
                   d.  Station Section Interlocked Gates                   :      40
                   e.  Sliding Type Boom at Interlocked gates              :      69(Tfc -39& Engg-30)
                   f.  Electrically Operated Lifting Barriers              :          28 (Tfc-16& Engg-12)


                  Power Supply Arrangement

                   a.  Full IPS                                            :      57
                   b.  Mini IPS                                            :      45
                   c.  Solar Panels at Stations                            :      11
                   d.  Solar Panels at LC gates                            :      33

                 Data Loggers

                   a.  Stations/Cabin                                      :      58
                   b.  LC gates/ Auto Sections/Huts                        :      74 (RTUs)




                                 [[[
                                                                                                   Page 1 of 10