Page 72 - Basic PD Theory
P. 72
References
H. References
1. IEEE 1434-2001, IEEE Guide to the Measurement of Partial Discharges in Rotating Machinery.
2. G.C. Stone et al, ‘Electrical Insulation for Rotating Machines’, IEEE Press –Wiley, Jan 2004.
3. Sedding, Howard, “Basics of Rotating Machine Partial Discharge Testing,” Canadian Electrical Association - Fourth
International Conference on Generator and Motor Partial Discharge Testing Proceedings, Houston, Texas, May 22-24,
1996.
4. Kurtz and G.C. Stone, “ Diagnostic testing of generator insulation, Part II - An improved partial discharge test,” Canadian
Electrical Association Research Report, RP76-17, 1978.
5. Iris Power LP, “Installation Guide for Epoxy-mica Couplers on Hydrogenerators,” 1997.
6. J.F. Lyles, T.E. Goodeve, G.C. Stone, “Using Diagnostic Technology for Identifying Generator Winding Measurement
Needs,” Hydro Review, June 1993, p58.
7. S.R. Campbell et al, “Practical On-Line PD Tests for Turbine Generators and Motors,” IEEE Trans EC, June 1994, p281.
8. G.C. Stone, “Partial Discharge Part XXV: Why PD Calibration is Difficult in Motors and Generators,” IEEE Electrical
Insulation Magazine, Jan/Feb 1998, pp. 9-12.
9. V. Warren, “How Much PD is too Much PD”, Iris Rotating Machine Conference, March 2005.
10. G.C. Stone et. al., “Unusual PD Pulse Phase Distributions in Operating Rotating Machines”, IEEE Trans DEI, Nov j4,
1995, p567
11. V. Warren, “PD – A Progress Report”, Iris Rotating Machine Conference, New Orleans, LA, June 2004.
12. Iris Power LP, “Installation Guide for PDA Couplers,” 2000.
13. Iris Power LP, “Installation Guide for BUS Couplers,” 2004.
14. Iris Power LP, “Installation Guide for Stator Slot Coupler,” 2003.
15. Iris Power LP, “Verification Guide,” 2004.
Guides/Standards
[1] ANSI/IEEE Std 1: General Principles for Temperature Limits in the Rating of Electrical Equipment
[2] IEEE Std 4: Standard Techniques for High Voltage Testing
[3] IEEE Std 62: Guide for Field Testing Power Apparatus Insulation
[4] IEEE Std 43: Recommended Practice for Testing Insulation Resistance of Rotating Machinery
[5] IEEE Std 95: Recommended practice for Insulation Testing of Large AC Rotating Machinery with High Direct Voltage
[6] IEEE Std 112: Standard Test Procedures for Polyphase Induction Motors and Generators
[7] IEEE Std 286: Recommended Practice for Measurement of Power-Factor Tip-Up of Rotating Machinery Stator Coil
Insulation
[8] IEEE Std 432: Guide for Insulation Maintenance for Rotating Electrical Machinery (5 hp to less than 10,000 hp)
[9] IEEE Std 522: Guide for Testing Turn-to-Turn Insulation on Form-Wound Stator Coils for Alternating-Current Rotating
Electric machines
[10] IEEE Std 1434: Guide to the Measurement of Partial Discharges in Rotating Machinery
[11] NEMA Standard Publication No. MG 1, Motors and Generators
[12] IEC/TS 60034-27-2 for 1CD, “Part 27-2: On-line partial discharge measurements on the stator winding insulation of
rotating electrical machines,” International Electrotechnical Commission, 2011.
www.irispower.com