             Notes:                                                 2.  Hoisting or lowering electric tools by their cords is
                                                                      prohibited. 1707(a)
               »  The followings shall not be required to be grounded.
               2395.45                                           D.  Powder-actuated tools (PAT) shall be approved for their
                                                                    intended use as defined in 1505, or have California approval
               i.  Listed portable tools or utilization equipment   numbers. 1684(a)(1),(2)
                 likely to be used in wet and conductive locations
                 if supplied through an isolating transformer with   1.  Only trained workers holding a valid operator’s card may
                 an ungrounded secondary of not over 50 volts.        use a PAT. 1685(a)(1)
               ii.  Listed or labeled portable tools and utilization   2.  Containers must be lockable and bear a label that says
                 equipment protected by an approved system            POWDER-ACTUATED TOOL on the outside. The storage
                 of double insulation. Where such a system is         container must be kept under lock and key. 1687(a)
                 employed, the equipment shall be distinctively     3.  The PAT must be provided with the following:
                 marked.
                                                                      a.  An operating and service manual
               »  Double-insulated type power-operated tools are not
               required to be grounded.                               b.  A power load and fastener chart
        B.  Guards required by the SOs must not be removed or         c.  An inspection and service record
          deactivated. 3942                                           d.  Repair and servicing tools. 1687(b)
        C.  Control switches for powered hand tools are subject to the   4.  Limitations on the use of PATs are as follows:
          regulations noted below:
                                                                      a.  Workers must not leave the tool unattended. 1690(b)
          1.  The following tools must be equipped with a constant-
             contact (dead-man) on-off switch: 3557(a)                b.  Workers must not use the tool:
             a.  Drills                                                  01.  In an explosive environment. 1690(a)
             b.  Tappers                                                 02.  On hard or brittle material. 1690(c)
             c.  Fastener drivers                                        03.  On easily penetrated or thin materials or materials
                                                                            of questionable resistance unless backed.
             d.  Grinders
                                                                            1690(d)
             e.  Disc and belt sanders
                                                                         04.  Within a 1/2 in. of the edge of steel. 1690(e)
             f.  Reciprocating saws
                                                                         05.  Within 3 in. of the edge of masonry. 1690(f)
             g.  Circular saws
                                                                         06.  On thin concrete. 1690(g)
             h.  Chain saws
                                                                         07.  On spalled areas. 1690(h)
             i.  Concrete vibrators
                                                                         08.  On existing holes. 1690(i)
             j.  Concrete breakers
                                                                    5.  Requirements for operating PATs are as noted:
             k.  Concrete trowels
                                                                      a.  Eye or face protection is required for operators and
             l.  Powered tampers                                         assistants. 1691(b)
            m.  Jack hammers                                          b.  Operators must inspect the tool before using it.
                                                                         1691(c)
             n.  Rock drills
                                                                      c.  Defective tools must not be used. 1691(d)
             o.  Tools similar to those above
                                                                      d.  Tools must not be loaded until ready for use. 1691(g)