Page 84 - Safety Memo
P. 84

Back To TABLE
          3.  An employee entering a bell-bottom pier hole or other   2.  No source of ignition is permitted indoors or outdoors
             deep or confined-footing excavation shall wear a          where vapor or gas concentrations may reasonably be
             harness that has a lifeline attended by another employee.   expected to exceed 25% of the LEL. 5416(c)
             1541(g)(2)(B)
                                                                    3.  Employers need to be aware that most flammable vapors
          4.  Shafts in other than hard, compact soil shall be        are toxic even at a very low concentration and can cause
             completely lagged and braced. 1542(c)(1)                 adverse health effects. Employers must have control
                                                                      measures to keep employees safe.
          5.  Head protection is required for workers who enter a well
             or shaft. 3381                                           Note: Check also for confined space conditions and
                                                                      hazardous locations. 5158, 2540.1, Confined Spaces
          6.  Shafts more than 20 ft. deep are subject to the TSOs.   section of this guide.
             8403(a)
          7.  Provide mechanical exhaust ventilation system and
             forced air blower or both for shafts 20 ft. or less which   Fall Protection
             employees enter and where hazardous atmosphere
             exists or reasonably expected to exist due to internal   T8 CCR includes fall protection standards in various sections of
             combustion engine operation. 1533(b)                the GISOs, CSOs, TSOs, and ESOs. These standards reflect the
                                                                 levels of the fall hazards associated with each activity.
        Explosion Hazards                                        A.  The factors affecting the level of hazard include the following:
                                                                    1.  Fall height
        At times employees may be exposed to explosion hazards
        without their knowledge. In addition to substances (such as   2.  Level of hazard awareness and skill of the employee
        dynamite) that are designed specifically for the purpose of   3.  Physical work environment (e.g., conditions affecting the
        creating explosions, there are substances that will cause an   stability of the employee on the work surface)
        explosion when present in certain concentrations and exposed
        to an ignition source. SOs to control these hazards include:  4.  Duration of exposure to the fall hazard
                                                                      Note: Because factors 2, 3, and 4 listed above vary
        A.  Combustible dust:
                                                                      with different trades and activities, the regulatory
          1.  Combustible dust concentrations must be controlled at   requirements for fall protection reflect those differences.
             or below 25% of the lower explosive limit (LEL) unless   Below find definitions and selected fall protection
             all ignition sources are eliminated or identified and     requirements:
             specifically controlled. 5174(a)
                                                                 B.  A personal fall protection (PFP) system prevents a worker
          2.  Accumulated and settled combustible dusts must be     from falling or— if the worker is falling— stops the fall.
             cleaned up to prevent a fire or explosion. 5174(b)      PFP systems include guard rails, safety nets, personal
          3.  Cleaning with compressed air and blowing combustible   fall restraint systems, personal fall arrest systems, and
             dust may be done only when other methods cannot        positioning device systems.
             be used, when possible sources of ignition have been   1.  Guardrails are required to guard the open sides of all work
             eliminated, and when hoses and nozzles are grounded.     surfaces that are 7 1/2 ft. or higher or workers must be
             5174(f)                                                  protected by other means. The railing must be made from
        B.  Flammable vapors:                                         select lumber (Doug Fir#1 or better 1500 Psi or equivalent)
                                                                      and must consist of a top rail 42 in. to 45 in. high, 2" x 4"
          1.  Ventilation in enclosed places must be sufficient to     (min.,; a 1" x 6" mid-rail halfway between the top rail and
             prevent flammable vapor or gas concentrations from        the floor, and support posts at least 2" x 4" at 8 ft. o.c.
             exceeding 25% of the LEL. 5416(a)
                                                                    2.  A personal fall restraint (PFR) system is used to prevent
                                                                      an employee from falling. It consists of anchorages,
    56    Cal/OSHA Pocket Guide for the Construction Industry | June 2015  Cal/OSHA Pocket Guide for the Construction Industry | June 2015    57