Page 12 - MN_011947_R00_400 TRIO_SITE
P. 12

Installation

              CAUTION:  All  connections  to  power  supply,  input  and  output  connectors  must  be
              carried out only with amplifier off.

         Recommended wire gauge & fuse
              Positive / negative power supply cable  ________________________________  11 AWG
              Output cables wire gauge (LOW OUT) _________________________________13 AWG
              Output cables wire gauge (MID OUT / HIGH OUT) _______________________  15 AWG
              Remote cable ____________________________________________________  18 AWG




              Protection fuse or circuit breaker________________________________________  20A
              Wire gauge calculated based in a 13,12 feets maximum lenght. For greater distances,
              increase the cable gauge to avoid power losses.
              Caution: Using wire gauges below the recommendation will result in power loss and
              overheating of wiring.
              Check polarity and never reverse power supply cables due to the risk of damage to the
              amplifier.
              It is compulsory to install a protection fuses or circuit breakers as close as possible from
              batteries.


                                                               Head Unit

                                    Remote Cable 18 AWG

                                                       Wire Input:
                                                       If you choose to use this input, you won’t
                                        GND
                                                       need  to  connect  the  RCA’S  cable  and
                                                       remote signal.
                                        12V
                                                        *Illustrative images
                                      11 AWG  11 AWG

                                                                      RCA Cable
                                                                       Taramps
                                   LOW OUT
                        2,5mm² (13 AWG)  MID OUT
                         1,5mm² (15 AWG)  HIGH OUT
                          1,5mm² (15 AWG)





                  Three way box

         Note: The 400 TRIO has a built - in passive filter for in each MID and HIGH outs..
                                                                               11
   7   8   9   10   11   12   13   14