Page 61 - Green Builder July-August 2019 Issue
P. 61

www.greenbuildermedia.com/code-arena

 CODE ARENA                                                                                                   Down to business. Revisions to
               CREDIT: KWANGMOOZAA ISTOCK                                                                     International Energy Conservation
                                                                                                              insulation, heating and cooling
 The Latest Rules, Regulations and Codes Impacting Sustainable Construction                                   regulations were among the key
                                                                                                              discussions at this year’s
                                                                                                              Code (IECC) Committee Action
                                                                                                              Hearings for Group B Codes.
































                          Table R402.1.2 (IRC N1102.1.2)                     of prescriptive options and show the full range of equivalent
                             Insulation and Fenestration                     insulation options (e.g., cavity only, hybrid cavity + continuous,
                                                                             and continuous only).
                            Requirements by Component                      4. Address concerns that the prescriptive table favors certain options
                                                                             over others by excluding viable options in some climate zones.
                    Climate Zone   Wood-Frame Wall R-Value                 5. Provides more exibility to coordinate insulation options with
                                                                             vapor retarder provisions in the building code, which vary by
                    1              13 or 0+10 h                              climate as well as insulation strategy. The proposed exibility
                                                                             gives users more choice between insulation options that provide
                    2              13 or 0+10 h                              equivalent assembly U-factor (as a minimum requirement of

                    3              20 or 13+5   or 0+15  h                   the energy code), yet have di­erent capabilities and functions
                                            h
                                                                             with respect to comfort, air tightness, moisture control, thermal
                    4 except Marine  20 or 13+5   or 0+15  h
                                            h
                                                                             bridging mitigation, and other factors that are important to an
                    5 and Marine 4  20 or 13+5   or 0+15  h                  overall code-compliant wall assembly.
                                            h
                    6              30 or 20+5   or 13+10   or 0+20  h        The reason statement for this proposal also contains a number of
                                            h
                                                     h
                                                                           calculation spreadsheets for the di­erent insulation levels/respective
                    7 and 8        30 or 20+5   or 13+10   or 0+20  h      climate zones.
                                                     h
                                            h
                                                                             COMMITTEE ACTION: Approved as Submitted: “This provides
                    h.  The first value is cavity insulation, the second value is continuous
                    insulation. For example, “13+5” means R-13 cavity insulation plus   additional options for compliance. It simpli†es code language and
                    R-5 continuous insulation.                             encourages users to look at all the associated issues (Vote: 8-3).”
                                                                             COMMENTARY: If for no other reason than the 8-3 committee vote,
                     insulation, because in the 2018 IECC, an equivalent cavity   this will probably have comments †led. However, it seems to have
                     insulation-only option is missing in Climate Zones 6-8.  positive momentum heading into October’s hearing.
                   2. Provide for equivalent continuous insulation-only options, which
                     are also are missing.                                 RE223-19 (APPENDIX RB)
                   3. Provide the table with a simple-yet-complete set of insulation     PROPOSAL: This proposal would create a new appendix for zero-
                     options for location of insulation on wood-frame wall assemblies   energy residential buildings. This section, if adopted, would require
                     for each climate zone, which would improve the usefulness   the rated design to have a score less than or equal to the values
                   www.greenbuildermedia.com                                                     July/August 2019 GREEN BUILDER  59




          58-60 GB 0719 Code Arena.indd   59                                                                                    7/17/19   9:34 AM
   56   57   58   59   60   61   62   63   64   65   66