Page 16 - Redco Forestry Solutions
P. 16

  For more information on RedcoTM products please call: 1 833 381 1195
BEARING CLEARANCE TABLES
Table A - SHAFT RUNNING CLEARANCE
If the shaft diameter in inches is: 1 2 Clearance in inches is: .007 .010 .032
4
5
10
11 .028
12 .030
3
Table B - BEARING WALL EXPANSION CLEARANCE (only for normal operating temperatures)*
If the bearing wall thickness is: 1/8 1/4 3/8 1/2 5/8 Clearance in inches is: .002 .004 .006 .008 .010
3/4 7/8 1 .012 .015 .017
1 1/4 .020
1 1/2 .024
1 3/4 2 .028 .033
Table C - PRESS FIT INTERFERENCE CLEARANCE (only if press fit)
If housing I.D. in inches is: 2 3 4 5 6
13
Clearance in inches is: .007 .009 .011 .012 .013 .015 .021
10 .018
11 .019
12 .020
Table D - MOISTURE EXPANSION CLEARANCE (only if water-lubricated bearing)**
If bearing wall thickness in inches is: 1/8 1/5 1/4 3/8 1/2 3/4 1 or more
If bearing is press fit, add clearances A, B, C. Then, add the total to the shaft diameter. The result is the finished inside diameter of the plastic bearing.
* - Plastics are subject to many variables (ie. Moisture, cold, heat, etc.) when being machined for specific applications.
** - If lubrication is supplied to a plastic bearing the load and life are increased, dependent on the type and volume of lubricant.
.013
.015
6 7 8 9 .018 .020 .022
.024
.026
7
8 9 .016 .017
































































   14   15   16   17   18