Page 307 - Catalogul Medicului 2019-2020_Final
P. 307
FIRST AID - PARAMEDICAL - EMERGENCY
CAPNOGRAPH AND OXIMETER 0123
• 33698 CAPNOGRAPH AND OXIMETER PC-900B 510(K)
This innovative and handheld capnograph and oximeter is
ideal for monitoring the most severe conditions of patients.
It provides reliable SpO and pulse rate measurements thanks
2
to its unique MoveOxy™ technology specially conceived for PC software for data review and analysis
SpO . It offers an accurate monitoring even in weak pulse Software (GB only) can be freely
2
signals condition and reliable monitoring in movement. downloaded
Display of graphical trends and plethysmographic waveform.
- 3.5" TFT display showing EtCO , RR and SpO , PR
2
2
- lung pressure and temperature compensation (BTPS
compensation)
- for intubated or non-intubated patients Wireless connection
- graphic trend storage up to 24 hours Bluetooth printer
- USB cable to transfer data on PC
- wireless module to connect to Bluetooth printer Silicone
Internal languages: GB, IT, ES, NL protection case
Water fi lter, sampling line and airway adapter
STANDARD ACCESSORIES
must be changed anytime you use it. 2 water fi lters USB data cable Support base
• 34351 ADULT SpO RUBBER PROBE - reusable 2 sampling lines Nasal CO sampling cannula Manual GB, IT
2
2
• 34345 ADULT SpO CLIP PROBE - reusable - spare 2 airway adaptors Silicone protective case
2
• 34347 PEDIATRIC SpO PROBE - reusable SpO probe Carrying bag
2
2
• 34349 NEONATAL SpO Y PROBE - reusable
2
• 33699 WATER FILTER
• 33700 SAMPLING LINE
• 33701 AIRWAY ADAPTER Support base 34345 34351 34347
• 34172 NASAL CANNULAS Reusable SpO adult probe Reusable SpO adult Reusable pediatric SpO 2
2
2
rubber probe probe
TECHNICAL SPECIFICATIONS
EtCO SpO
2
2
EtCO /CO range: 0-150 mmHg (0-20 kPa, or 0-20% (V/V)) Oximetry saturation range: 0-100%
2
2
Accuracy: ±2 mmHg when 0-40 mmHg Accuracy: ±2% when 70-100%, ±3% when 50-69%
±5% (reading) when > 41-70 mmHg Trend length: 24 hours
±8% (reading) when > 71-100 mmHg Pulse rate
±10% (reading) when > 101-150 mmHg Range: 30-250 bpm
Update: Every breath, 10, 20 or 30 sec selectable Accuracy: ±2 bpm or ±2% (reading) when 30-250 bpm
Trend length: 24 hours Trend length: 24 hours
Respiration rate Power supply
Range: 3-150 breaths/min AC input consumption: 100-250 V, 50-60 Hz, 5 W
Accuracy: ±1% (reading) or ±1 times/min whichever is greater Battery: Built-in rechargeable lithium battery - 3.6 V, 3000 mAh
Trend length: 24 hours Working time: 10 hours
Flux: 50-250 cc/min selectable Dimension - Weight 70x160xh 40 mm - 600 g
OXY-200 DESKTOP PULSE OXIMETER ETCO +SPO Size: 170x88x44 mm
2
2
Audible and visible alarm for over-limit and low battery.
Continuous working PORTABLE OXI-CAPNOGRAPHY MONITOR
time: more than 1 hour Upper and lower alarm limit can be set. • 33702 OXY CAPNOGR. HUMAN
Handle for • 33703 OXY CAPNOGR. VET
transport
Portable multifunctional Capnography
monitor providing SpO , Pulse, EtCO ,
2
2
Respiration with accuracy 72 hours
and reliable performance. memory
Light and large LCD display with trend
providing graphical SpO , function
2
EtCO and Trend function all in one
2
design. Through optional software
link to PC via USB. Filter replacement
35101 after 8 hours of use. Supplied with adult
Screen brightness, volume and 320x240 TFT screen Menu operation sensor, AC adapter, sampling tube,
display mode can be adjusted and LCD easy to use airway adapter, fi lter cartridge,
• 35101 OXY-200 DESKTOP PULSE OXIMETER carrying bag, 4 AA rechargeable batteries.
with monitor and battery • 33705 FILTER - box of 10
Portable oximeter displays SpO , PR, bar graph, PI, pulse • 33706 SAMPLING TUBE 1.2 m - box of 20
2
waveform and battery power. Multiuser data storage and • 33708 VET PROBE - spare
review. Stored data can be uploaded to PC in real time.
Finger adult probe, battery and software for PC download are
included.
• 35102 LITHIUM RECHARGEABLE BATTERY - spare
• 35105 SpO FINGER-PROBE - adult or child over 15 kg - spare TECHNICAL SPECIFICATIONS
Accuracy
Range
2
• 35106 PEDIATRIC PROBE 3-15 kg - reusable SpO Saturation: 0% to 100% ±2% between 80% to 100%
2
• 35107 NEONATAL PROBE <3 kg - reusable - needs 35108 Pulse Rate: 30 bpm to 250 bpm ±1% of full scale
• 35109 ADULT NEONATAL PROBE* - disposable - needs 35108 EtCO : Range Average
4 breaths of EtCO
0 mmHg to 100 mmHg
2
• 35108 EXTENSION CABLE necessary for 35107, 35109 Respiration rate 0 l/min to 99 l/min 8 breaths of respiration rate
2
TECHNICAL SPECIFICATIONS Memory: 72 hours
Power supply: 100-240 V, 50/60 Hz Output interface: USB
Default Alarm Settings:
rechargeable lithium battery SpO upper limit: 100% SpO lower limit: 50%
SpO measuring range: 0-100% ±2% (between 70-100%) Resolution: 1% Pulse rate upper limit: 250 bpm Pulse rate lower limit: 30 bpm
2
2
2
Pulse rate: 30-250 bpm ±2 bpm or ±2% (select larger) Resolution: 1 bpm EtCO upper limit: 100 mmHg EtCO lower limit: 0 mmHg
2
2
PI measuring range: 0-20% ±1% (between 1%-20%) Resolution: 0.1% Resp upper limit: 99 l/min Resp lower limit: 0 l/min
Size: 269x222x79 mm - Weight: 1 kg User manual (GB, IT) Power 4 AA rechargeable batteries 6 volts or AC/DC adapter
*Suitable for adult over 40 kg (fi nger) or neonate less than 3 kg (foot)
296