Page 22 - 12558 Drexler Builder Binder.pdf
P. 22

standard for Code compliance.
                              1.13   Handrails shall remain securely   If handrails are not firmly attached to the   Surfaces altered incident to any repair
                                   attached to concrete stairs.  concrete stairs, the Builder shall take such   will be finished or touched up to match
                                                               steps necessary as to attach the rails   the surrounding area as closely as
                                                               securely.                      practical.
                              1.14  Concrete stairs or stoops shall not   If the stairs or stoops settle or heave, or   Surfaces altered incident to any repair
                                   settle or heave in an amount equal to or   separate from the Home in an amount   will be finished or touched up to match
                                   exceeding 3/8 of an inch.  Concrete   equal to or exceeding the standard above   the surrounding area as closely as
                                   stairs or stoops shall not separate from   Builder shall take such action as necessary  practical.
                                   the Home in an amount equal to or   to bring the variance within the standard.
                                   exceeding one inch, including joint
                                   material.
        DRIVEWAYS             1.15  A driveway will not have a negative   If a driveway has a negative slope due to   Surfaces altered incident to any repair
                                   slope unless due to site conditions, the   site conditions, it shall have swales or   will be finished or touched up to match
                                   lot is below the road.      drains properly installed to prevent water   the surrounding area as closely as
                                                               from entering into the garage.  If a driveway   practical.
                                                               has a negative slope that allows water to
                                                               enter the garage in normal weather
                                                               conditions, the Builder shall take such
                                                               action as necessary to bring the variance
                                                               within the standard.
        DETACHED SLABS        1.16  Concrete floor slabs in detached   If a concrete floor slab in a detached   Surfaces altered incident to any repair
                                   garages, carports or porte-cocheres   garage, carport or porte-cochere does not   will be finished or touched up to match
                                   shall not have excessive pits,   meet the standards, the Builder shall take   the surrounding area as closely as
                                   depressions, deterioration or   such action as necessary to bring the   practical.
                                   unevenness.  Separations or cracks in   variance within the standard.
                                   these slabs shall not equal or exceed
                                   3/16 of an inch in width, except at
                                   expansion joints, or 1/8 of an inch in
                                   vertical displacement.
                                                          2. FRAMING
        WALLS                 2.1  Walls shall not bow or have   If a wall does not meet the standard, the   Surfaces altered incident to any repair
                                   depressions that equal or exceed  of   Builder shall take such action as necessary  will be finished or touched up to match
                                   an inch out of line within any 32-inch   to bring the variance within the standard.  the surrounding area as closely as
                                   horizontal measurement as measured                         practical.
                                   from the center of the bow or
                                   depression or  of an inch within any
                                   eight-foot vertical measurement.
                              2.2    Walls shall be level, plumb and square   If a wall does not meet the standard, the   Surfaces altered incident to any repair
                                   to all adjoining openings or other walls   Builder shall take such action as necessary  will be finished or touched up to match
                                   within 3/8 of an inch in any 32-inch   to bring the variance within the standard.  the surrounding area as closely as
                                   measurement.                                               practical.
                              2.3  A crack in a beam or a post shall not   If a crack in the beam or post fails to meet   Surfaces altered incident to any repair
                                   equal or exceed  of an inch in width at   the standard, the Builder shall take such   will be finished or touched up to match
                                   any point along the length of the crack.  action as necessary to bring the variance   the surrounding area as closely as
                                                               within the standard.           practical.
                              2.4  A non-structural post or beam shall not   Warping or twisting shall not damage beam   Surfaces altered incident to any repair
                                   have a warp or twist equal or exceeding   pocket.  If a non-structural post or beam   will be finished or touched up to match
                                   one inch in eight-feet of length.  fails to meet the standard, the Builder shall   the surrounding area as closely as
                                                               take such action as necessary to bring the   practical.
                                                               variance within the standard.
                              2.5   Exterior sheathing shall not delaminate   If exterior sheathing delaminates or swells,   The Owner shall not make
                                   or swell.                   the Builder shall take such action as  penetrations in the exterior finish of a
                                                               necessary to bring the variance within the   wall that allow moisture to come in
                                                               standard.                      contact with the exterior sheathing.
                              2.6  An exterior moisture barrier shall not   If an exterior moisture barrier allows an   The Owner shall not make
                                   allow an accumulation of moisture   accumulation of moisture inside the barrier,   penetrations through the exterior
                                   inside the barrier.         the Builder shall take such action as  moisture barrier that permit the
                                                               necessary to bring the variance within the   introduction of moisture inside the
                                                               standard.                      barrier.
        CEILINGS              2.7  A ceiling shall not bow or have   If a ceiling has a bow or depression that is   Surfaces altered incident to any repair
                                   depressions that equal or exceed  of   greater than the standard, the Builder shall   will be finished or touched up to match
                                   an inch out of line within a 32-inch   take such action as necessary to bring the   the surrounding area as closely as
                                   measurement as measured from the   variance within the standard.  practical.
                                   center of the bow or depression running
                                   parallel with a ceiling joist.
        SUB-FLOORS            2.8   Under normal residential use, the floor   If the floor makes excessive squeaking and   Surfaces altered incident to any repair
                                   shall not make excessive squeaking or   popping sounds under normal residential   will be finished or touched up to match
                                   popping sounds.             use, the Builder shall take such action as   the surrounding area as closely as
                                                               necessary to bring the variance within the   practical.
                                                               standard.
                              2.9  Sub-floors shall not delaminate or swell   If a sub-floor delaminates or swells to the   Exposed structural flooring, where the
                                   to the extent that it causes observable   extent that it affects the flooring covering   structural flooring is used as the